Usual Dose of Simvastatin Does Not Inhibit Plaque Progression and Lumen Loss at the Peri-Stent Reference Segments after Bare-Metal Stent Implantation: A Serial Intravascular Ultrasound Analysis

Article information

Korean J Intern Med. 2010;25(4):356-363
Publication date (electronic) : 2010 November 27
doi : https://doi.org/10.3904/kjim.2010.25.4.356
The Heart Center of Chonnam National University Hospital, Chonnam National University Research Institute of Medical Sciences, Gwangju, Korea.
Correspondence to Myung Ho Jeong, M.D. Heart Research Center of Chonnam National University Hospital, Hak-dong, Dong-gu, Gwangju 501-757, Korea. Tel: 82-62-220-6243, Fax: 82-62-228-7174, myungho@chollian.net
Received 2010 January 25; Revised 2010 March 05; Accepted 2010 June 11.

Abstract

Background/Aims

The aim of this study was to assess the effects of a usual dose of simvastatin (20 mg/day) on plaque regression and vascular remodeling at the peri-stent reference segments after bare-metal stent implantation.

Methods

We retrospectively investigated serial intravascular ultrasound (IVUS) findings in 380 peri-stent reference segments (184 proximal and 196 distal to the stent) in 196 patients (simvastatin group, n = 132 vs. non-statin group, n = 64). Quantitative volumetric IVUS analysis was performed in 5-mm vessel segments proximal and distal to the stent.

Results

IVUS follow-up was performed at a mean of 9.4 months after stenting (range, 5 to 19 months). No significant differences were observed in the changes in mean plaque plus media (P&M) area, mean lumen area, and mean external elastic membrane (EEM) area from post-stenting to follow-up at both proximal and distal edges between the simvastatin and non-statin group. Although lumen loss within the first 3 mm from each stent edge was primarily due to an increase in P&M area rather than a change in EEM area, and lumen loss beyond 3 mm from each stent edge was due to a combination of increased P&M area and decreased EEM area, no significant differences in changes were observed in P&M, EEM, and lumen area at every 1-mm subsegment between the simvastatin and non-statin group.

Conclusions

A usual dose of simvastatin does not inhibit plaque progression and lumen loss and does not affect vascular remodeling in peri-stent reference segments in patients undergoing bare-metal stent implantation.

INTRODUCTION

Stent-edge and reference segment changes are composed of the evolution of plaque and/or vessel area changes, which can be visualized with intravascular ultrasound (IVUS) before and after stenting [1-7]. Serial IVUS examination of the plaque is very important because it can offer a relatively exact mechanism of plaque evolution.

Recent trials have demonstrated that lipidlowering therapy with statins improves clinical outcomes [8,9] and reduces the progression of atherosclerosis [10]. The beneficial effects of statins, beyond their lipid-lowering actions, mostly rely on their anti-inflammatory properties [11]. Simvastatin has also been shown to inhibit smooth muscle cell proliferations [12].

To the best of our knowledge, few data are available regarding the effects of statins on plaque regression and vascular remodeling in peri-stent reference segments. In the present study, we assessed the effects of a usual dose of simvastatin on plaque regression and vascular remodeling in peri-stent reference segments after the use of a bare-metal stent (BMS) using serial IVUS observations. Our hypothesis was that a usual dose of simvastatin would not affect plaque regression and vascular remodeling in peri-stent reference segments after BMS implantation.

METHODS

Study population

From January 2004 through December 2005, 196 patients who were treated with BMS implantation under the guidance of IVUS at Chonnam National University Hospital, Gwangju, Korea, were analyzed retrospectively. The patients were divided into two groups: the simvastatin group (n = 132) and the non-statin group (n = 64). For the simvastatin group, a 20 mg/day schedule of simvastatin was introduced from just after stent implantation through the follow-up period without discontinuation.

Among 392 peri-stent reference segments, 12 segments proximal to the stent edge were excluded because of their ostial location. Therefore, 380 peri-stent reference segments were available for analysis, which consisted of 184 segments proximal to the stent edges and 196 segments distal to the stent edges.

Cases of stent thrombosis, ostial stenting, far distal stenting with < 2.5 mm of reference diameter, and inadequate IVUS quality were excluded from the analysis. The protocol was approved by the institutional review board of Chonnam National University Hospital. Hospital records of patients were reviewed to obtain clinical and demographic variables.

Laboratory analysis

In all patients, serum was collected before stent implantation for measuring lipid profiles and high-sensitivity C-reactive protein. All laboratory values were measured after an overnight fast. The serum levels of total cholesterol, low-density lipoprotein-cholesterol, high-density lipoprotein-cholesterol, and triglycerides were measured using standard enzymatic methods. High-sensitivity cardiac C-reactive protein reagent (Beckman Coulter, Fullerton, CA, USA) was used for the quantitative determination of C-reactive protein in serum samples on a fully automated IMMAGE® Immunochemistry System (Beckman Coulter). The IMMAGE® Immunochemistry System utilizes proven rate nephelometry methodologies to provide specific, reproducible, quantitative protein results. Serum lipid profiles and high-sensitivity C-reactive protein were measured at baseline and at follow-up.

Stent implantation procedure

Patients received BMS implantation for de novo lesions in native coronary arteries having a reference diameter between 2.5 and 4.0 mm. Stent implantation was performed as previously described [13]. If residual stenosis occurred after stent implantation, adjunctive balloon angioplasty using a balloon with the same size as, or a larger size than, the stent was performed.

Quantitative coronary angiography (QCA)

Angiograms were analyzed with a validated QCA system (Phillips H5000 or Allura DCI program; Philips Medical Systems, Best, The Netherlands). Using the outer diameter of a contrast-filled catheter as the calibration standard, the minimal lumen diameter and reference diameter were measured in diastolic frames from orthogonal projections.

In-stent restenosis

Patients were examined for in-stent restenosis during the follow-up period. Angiographic restenosis was defined as ≥ 50% stenosis in the stented segment, including peri-stent reference segments within 5 mm from each stent edge at follow-up, or at least a 50% loss of the original gain in the minimal luminal diameter.

IVUS imaging protocol

IVUS examinations were performed at post-stenting and at follow-up after intra-coronary administration of 300 µg nitroglycerin using a commercially available IVUS system (Boston Scientific Corporation/SCIMed, Minneapolis, MN, USA). This system allows for digital storage of pullback sequences. The IVUS catheter was advanced distally to > 5 mm from the distal stent edges, and imaging was performed using retrograde pullback at an automatic pullback speed of 0.5 mm/sec proximally to > 5 mm from the proximal stent edges.

IVUS analysis

We performed IVUS analysis for the entire 5-mm proximal and distal stent edge segments. Both proximal and distal vessel segments were divided into 1-mm subsegments and analyzed. Using planimetry software (TapeMeasure; INDEC Systems Inc., Mountain View, CA, USA), volumetric analysis for each subsegments was performed. External elastic membrane (EEM) and lumen areas were measured, and plaque plus media (P&M) area (EEM-lumen area) and plaque burden (P&M area divided by EEM area) were calculated from each cross-sectional slice and were expressed as mean values (summation of each measured values at 1-mm subsegments divided by 5). Area changes (Δ values) for each measurement were calculated as follow-up minus post-stenting values.

Statistical analysis

The SPSS version 15.0 (SPSS Inc., Chicago, IL, USA) was used for all analyses. Continuous variables were presented as the mean value ± 1 SD and compared using paired or unpaired Student t tests or a nonparametric Wilcoxon test if the normality assumption was violated. Discrete variables were presented as percentages and relative frequencies; comparisons were conducted using a chi-square test or Fisher's exact test as appropriate. A p value < 0.05 was considered statistically significant.

RESULTS

Baseline characteristics and changes in serum lipid profiles and high-sensitivity C-reactive protein

No significant differences in patient demographic variables and medications, except for statin use, were observed (Table 1). At follow-up, total cholesterol, low-density lipoprotein-cholesterol, and triglyceride levels had significantly decreased, and high-density lipoprotein-cholesterol level had significantly increased, in the simvastatin group as compared to the non-statin group. High-sensitivity C-reactive protein levels were also significantly lower in the simvastatin group as compared to the non-statin group during follow-up (Table 2).

Table 1

Patient demographics and medications

Table 2

Coronary angiographic characteristics

QCA results and restenosis

No significant difference in baseline coronary angiographic findings and procedural results was observed between the simvastatin group and the non-statin group (Table 3). At follow-up, binary in-stent restenosis was present in 16% of the simvastatin group (21/132) and 20% of the non-statin group (13/64), and repeat revascularization was performed in 14% of patients in the simvastatin group (18/132) and 17% in the non-statin group (11/64). However, these differences were not significant (p = 0.3, p = 0.4, respectively).

Table 3

Coronary angiographic findings and procedural results

IVUS results

IVUS follow-up was performed at a mean of 9.4 months after stenting (range, 5 to 19 months). No stent edge dissection was noted at post-stenting. Post-stenting peri-stent reference segment minimum lumen sites were 3.1 ± 2.1 mm from their respective proximal stent edges and 2.9 ± 1.9 mm from their respective distal stent edges. Overall, within these sites, P&M area increased (proximal edge, +0.5 ± 0.3 mm2, p < 0.001; distal edge, +0.6 ± 0.4 mm2, p < 0.001), and lumen area (proximal edge, -1.1 ± 0.5 mm2, p < 0.001; distal edge, -1.0 ± 0.4 mm2, p < 0.001) and EEM area (proximal edge, -0.6 ± 0.3 mm2, p < 0.001; distal edge, -0.4 ± 0.3 mm2, p = 0.001) decreased from post-stenting to follow-up.

Using volumetric analysis, overall, mean P&M area increased (Δ = +0.5 ± 0.5 mm2, p < 0.001 at the proximal edge and Δ = +0.6 ± 0.4 mm2, p < 0.001 at the distal edge), and mean EEM (Δ = -0.4 ± 0.3 mm2, p < 0.001 at the proximal edge and Δ = -0.3 ± 0.3 mm2, p < 0.001 at the distal edge) and mean lumen area (Δ = -0.9 ± 0.5 mm2, p < 0.001 at the proximal edge and Δ = -0.9 ± 0.4 mm2, p < 0.001 at the distal edge) decreased from post-stenting to follow-up.

For the proximal edge, mean P&M area significantly increased, and mean lumen area and mean EEM area significantly decreased at follow-up in both the simvastatin and non-statin groups. However, no significant differences were observed in changes in mean P&M (simvastatin, +0.3 ± 0.2 mm2 vs. non-statin, +0.7 ± 0.4 mm2; p = 0.10), mean EEM (simvastatin, -0.4 ± 0.4 mm2 vs. non-statin, -0.4 ± 0.3 mm2; p = 1.0), and mean lumen (simvastatin, -0.7 ± 0.4 mm2 vs. non-statin, -1.1 ± 0.6 mm2; p = 0.11) areas from post-stenting to follow-up between the simvastatin and non-statin groups at the proximal edge. For the distal edge, mean P&M area significantly increased, and mean lumen area and mean EEM area significantly decreased at follow-up in both the simvastatin and non-statin groups. However, no significant differences were observed in changes in mean P&M (simvastatin, +0.4 ± 0.2 mm2 vs. non-statin, +0.7 ± 0.3 mm2; p = 0.18), mean EEM (simvastatin, -0.3 ± 0.3 mm2 vs. non-statin, -0.3 ± 0.2 mm2; p = 1.0), and mean lumen (simvastatin, -0.7 ± 0.4 mm2 vs. non-statin, -1.0 ± 0.6 mm2; p = 0.19) areas from post-stenting to follow-up between the simvastatin and non-simvastatin groups at the distal edge (Table 4, Fig. 1).

Table 4

Serial volumetric intravascular ultrasound analysis

Figure 1

Serial area changes (follow-up minus post-stenting) in mean plaque plus media (P&M), external elastic membrane (EEM), and lumen areas according to the simvastatin therapy at the proximal (A) and distal (B) peri-stent reference segments.

Although lumen loss within the first 3 mm from each stent edge was primarily due to an increase in P&M area rather than a change in EEM area, and lumen loss beyond 3 mm from each stent edge was due to a combination of increased P&M area and decreased EEM area, no significant differences were observed in changes in P&M, EEM, and lumen area at every 1-mm subsegment between the simvastatin and non-statin groups (Table 5).

Table 5

Changes in plaque plus media gain, lumen loss, and external elastic membrane are from the index to follow-up intravascular ultrasound

In-stent restenosis occurred in 34 patients, including 14 stent edge in-stent restenosis (6 proximal edges and 8 distal edges). More significant lumen losses accompanied by a greater increase in P&M area and a greater decrease in EEM area occurred in the in-stent restenosis group as compared to the no in-stent restenosis group from post-stenting to follow-up: 1) P&M area (in-stent restenosis group, +1.4 ± 0.9 mm2 vs. no in-stent restenosis group, +0.6 ± 0.4 mm2; p < 0.001); 2) EEM area (in-stent restenosis group, -0.9 ± 0.5 mm2 vs. no in-stent restenosis group, -0.3 ± 0.3 mm2; p = 0.001); 3) lumen area (in-stent restenosis group, -2.3 ± 1.4 mm2 vs. no in-stent restenosis group, -0.9 ± 0.5 mm2; p < 0.001) No significant differences were observed in changes in P&M, EEM, and lumen areas according to the presence/absence of the use of post-stenting adjunctive balloon angioplasty.

DISCUSSION

The results of this study demonstrate that usual dose-simvastatin therapy does not affect disease progression (plaque increase and lumen loss) and vascular remodeling in peri-stent reference segments in patients undergoing BMS implantation.

Several IVUS studies have demonstrated the effects of statins on plaque regression and vessel remodeling. Suzuki et al. [14] reported that plaque area decreased by 12% in patients who received a statin as compared to 13% increase in plaque area in those who did not receive a statin. Additionally, vessel area was not enlarged in patients treated with a statin, but did show positive remodeling in those who had plaque progression without a statin. Jensen et al. [15] reported a significant reduction (4.6%) in the lesion EEM area and in the lesion plaque area (5.9%), but no change in reference measurements after 12 months of simvastatin treatment. As a result, the remodeling index was reduced by simvastatin from 1.01 ± 0.12 to 0.95 ± 0.09. Petronio et al. [16] reported that therapy with 20 mg/day of simvastatin did not prevent intimal hyperplasia or in-stent restenosis, but it promoted atherosclerotic regression both at stented and nonstented sites in patients with normocholesterolemia who underwent coronary stenting. However, the main objectives of previous studies [14-16] have not been to assess the effects of statins on plaque regression and vascular remodeling in peri-stent reference segments in patients who underwent BMS implantation. In the present study, we sought to assess the effects of a usual dose of simvastatin (20 mg/day) on plaque regression and vascular remodeling at peri-stent reference segments; however, therapy with 20 mg/day of simvastatin did not regress plaque at either the proximal or distal edges from post-stenting to follow-up, and did not prevent in-stent restenosis at a mean of 9.4 months of follow-up after stenting.

The response of adjacent reference segments not covered by the stent is of major interest. Several studies have demonstrated lumen loss adjacent to the stent edge after BMS implantation. Hoffmann et al. [2] performed serial IVUS analysis at the most normal-looking cross section within a 10-mm segment proximal or distal to the stent, another midway between this slice, and the proximal or distal edge of the stent. In this study, the more distant reference segments showed a greater degree of remodeling (decrease in EEM area) than of tissue growth, whereas anatomic sections sampled at a point closer to the edge of the stent showed a similar amount of remodeling and a greater degree of cellular proliferation (increase in P&M area) as compared to the more distant reference segments. Mudra et al. [3] reported no relevant progression of the disease adjacent to the stent, despite a considerable plaque burden within the reference segments. Weissman et al. [4] analyzed reference segments 10 mm proximal and distal to the stent at index and follow-up. In this study, lumen loss in the adjacent reference segments, which was most pronounced within the first 2 mm of the stent edge, and lumen loss within 2 mm of the stent edge were due primarily to intimal proliferation. In contrast, beyond 2 mm, negative remodeling contributed more to lumen loss. In the present study, lumen loss within the first 3 mm from each stent edge was primarily due to an increase in P&M area rather than a change in EEM area. Lumen loss beyond 3 mm from each stent edge was due to a combination of increased P&M area and decreased EEM area.

The present study has some limitations. First, the present study is retrospective and therefore subject to limitations inherent to this type of clinical investigation. Second, this single-center study included only a small number of patients. Third, we did not assess changes in EEM, lumen, and plaque areas that were more distant from the stent edges, i.e., segments that were not affected by the stent or balloon. Fourth, we did not compare the effects of low-dose statin with moderate or high-dose statin therapy on plaque regression and vascular remodeling. Therefore, further prospective, randomized, large-scale studies are needed.

In conclusion, a usual dose of simvastatin does not inhibit plaque progression and lumen loss and does not affect vascular remodeling in peri-stent reference segments in patients undergoing BMS implantation.

Acknowledgements

This study was supported by a grant from the Korea Healthcare Technology R&D project (A084869), Ministry for Health, Welfare & Family Affairs, Korea.

Notes

No potential conflict of interest relevant to this article was reported.

References

1. Hoffmann R, Mintz GS, Popma JJ, et al. Chronic arterial responses to stent implantation: a serial intravascular ultrasound analysis of Palmaz-Schatz stents in native coronary arteries. J Am Coll Cardiol 1996;28:1134–1139. 8890806.
2. Hoffmann R, Mintz GS, Dussaillant GR, et al. Patterns and mechanisms of in-stent restenosis. A serial intravascular ultrasound study. Circulation 1996;94:1247–1254. 8822976.
3. Mudra H, Regar E, Klauss V, et al. Serial follow-up after optimized ultrasound-guided deployment of Palmaz-Schatz stents. In-stent neointimal proliferation without significant reference segment response. Circulation 1997;95:363–370. 9008450.
4. Weissman NJ, Wilensky RL, Tanguay JF, et al. Extent and distribution of in-stent intimal hyperplasia and edge effect in a non-radiation stent population. Am J Cardiol 2001;88:248–252. 11472702.
5. Jiménez-Quevedo P, Sabaté M, Angiolillo DJ, et al. Vascular effects of sirolimus-eluting versus bare-metal stents in diabetic patients: three-dimensional ultrasound results of the Diabetes and Sirolimus-Eluting Stent (DIABETES) Trial. J Am Coll Cardiol 2006;47:2172–2179. 16750681.
6. Serruys PW, Degertekin M, Tanabe K, et al. Vascular responses at proximal and distal edges of paclitaxel-eluting stents: serial intravascular ultrasound analysis from the TAXUS II trial. Circulation 2004;109:627–633. 14769685.
7. Honda Y, Grube E, de La Fuente LM, Yock PG, Stertzer SH, Fitzgerald PJ. Novel drug-delivery stent: intravascular ultrasound observations from the first human experience with the QP2-eluting polymer stent system. Circulation 2001;104:380–383. 11468196.
8. Cannon CP, Braunwald E, McCabe CH, et al. Intensive versus moderate lipid lowering with statins after acute coronary syndromes. N Engl J Med 2004;350:1495–1504. 15007110.
9. Hong YJ, Jeong MH, Lim JH, et al. The prognostic significance of statin therapy in acute myocardial infarction patients underwent percutaneous coronary intervention. Korean J Med 2003;65:426–435.
10. Nissen SE, Tuzcu EM, Schoenhagen P, et al. Effect of intensive compared with moderate lipid-lowering therapy on progression of coronary atherosclerosis: a randomized controlled trial. JAMA 2004;291:1071–1080. 14996776.
11. Libby P, Aikawa M. Mechanisms of plaque stabilization with statins. Am J Cardiol 2003;91(4A):4B–8B.
12. Corsini A, Mazzotti M, Raiteri M, et al. Relationship between mevalonate pathway and arterial myocyte proliferation: in vitro studies with inhibitors of HMG-CoA reductase. Atherosclerosis 1993;101:117–125. 8216498.
13. Walter DH, Schachinger V, Elsner M, Dimmeler S, Zeiher AM. Platelet glycoprotein IIIa polymorphisms and risk of coronary stent thrombosis. Lancet 1997;350:1217–1219. 9652563.
14. Suzuki M, Saito M, Nagai T, Saeki H, Kazatani Y. Prevention of positive coronary artery remodeling with statin therapy in patients with coronary artery diseases. Angiology 2006;57:259–265. 16703185.
15. Jensen LO, Thayssen P, Mintz GS, Carlier SG, Pedersen KE, Haghfelt T. Effect of simvastatin on coronary lesion site remodeling: a serial intravascular ultrasound study. Cardiology 2006;106:256–263. 16710086.
16. Petronio AS, Amoroso G, Limbruno U, et al. Simvastatin does not inhibit intimal hyperplasia and restenosis but promotes plaque regression in normocholesterolemic patients undergoing coronary stenting: a randomized study with intravascular ultrasound. Am Heart J 2005;149:520–526. 15864242.

Article information Continued

Figure 1

Serial area changes (follow-up minus post-stenting) in mean plaque plus media (P&M), external elastic membrane (EEM), and lumen areas according to the simvastatin therapy at the proximal (A) and distal (B) peri-stent reference segments.

Table 1

Patient demographics and medications

Table 1

Values are presented as mean ± SD or number (%).

NSTEMI, non-ST segment elevation myocardial infarction; STEMI, ST segment elevation myocardial infarction; ACE, angiotensin-converting enzyme; ARB, angiotensin receptor blocker.

Table 2

Coronary angiographic characteristics

Table 2

Values are presented as mean ± SD.

LDL, low-density lipoprotein; HDL, high-density lipoprotein.

Table 3

Coronary angiographic findings and procedural results

Table 3

Values are presented as mean ± SD or number (%).

MLD, minimal lumen diameter.

Table 4

Serial volumetric intravascular ultrasound analysis

Table 4

Values are presented as mean ± SD.

EEM, external elastic membrane; P&M, plaque plus media.

aIndicates p value < 0.05 between post-stenting value and follow-up value.

Table 5

Changes in plaque plus media gain, lumen loss, and external elastic membrane are from the index to follow-up intravascular ultrasound

Table 5

Values are presented as mean ± SD.

EEM, external elastic membrane; P&M, plaque plus media.