<?xml version="1.0"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD v1.0 20120330//EN" "JATS-archivearticle1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="editorial"><?properties open_access?><front><journal-meta><journal-id journal-id-type="nlm-ta">Korean J Intern Med</journal-id><journal-id journal-id-type="iso-abbrev">Korean J. Intern. Med</journal-id><journal-id journal-id-type="publisher-id">KJIM</journal-id><journal-title-group><journal-title>The Korean Journal of Internal Medicine</journal-title></journal-title-group><issn pub-type="ppub">1226-3303</issn><issn pub-type="epub">2005-6648</issn><publisher><publisher-name>The Korean Association of Internal Medicine</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="pmid">25589831</article-id><article-id pub-id-type="pmc">4293559</article-id><article-id pub-id-type="doi">10.3904/kjim.2015.30.1.27</article-id><article-categories><subj-group subj-group-type="heading"><subject>Editorial</subject></subj-group></article-categories><title-group><article-title>Can improvements in our physiological understanding yield information on the utility of endothelial progenitor cell capture stents?</article-title></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name><surname>Kang</surname><given-names>Hyun-Jae</given-names></name><xref ref-type="aff" rid="A1-kjim-30-27"/></contrib></contrib-group><aff id="A1-kjim-30-27">Department of Internal Medicine, Seoul National University Hospital, Seoul, Korea.</aff><author-notes><corresp>
Correspondence to Hyun-Jae Kang, M.D. Department of Internal Medicine, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul 110-744, Korea. Tel: +82-2-2072-2279, Fax: +82-2-762-2231, <email>nowkang@snu.ac.kr</email></corresp></author-notes><pub-date pub-type="ppub"><month>1</month><year>2015</year></pub-date><pub-date pub-type="epub"><day>30</day><month>12</month><year>2014</year></pub-date><volume>30</volume><issue>1</issue><fpage>27</fpage><lpage>28</lpage><history><date date-type="received"><day>02</day><month>12</month><year>2014</year></date><date date-type="accepted"><day>04</day><month>12</month><year>2014</year></date></history><permissions><copyright-statement>Copyright &#xA9; 2015 The Korean Association of Internal Medicine</copyright-statement><copyright-year>2015</copyright-year><license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by-nc/3.0/"><license-p>This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (<ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by-nc/3.0/">http://creativecommons.org/licenses/by-nc/3.0/</ext-link>) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p></license></permissions></article-meta></front><body><p>See Article on Page <related-article related-article-type="commentary-article" id="d35e93-kjim-30-27" vol="30" page="42" ext-link-type="pmc">42-48</related-article></p><p>At the 2006 meeting of the European Society of Cardiology (ESC), Camenzind et al. [<xref rid="B1-kjim-30-27" ref-type="bibr">1</xref>] reported that patients were at risk of very late stent thrombosis when first-generation drug-eluting stents (DES) were placed. This warning introduced a new era of controversy; the clinical implications of re-endothelialization after stent implantation remain intensively debated today. Topics include the adequate duration of dual antiplatelet treatment, stent-related endothelial dysfunction, and the safety and efficacy of bare-metal stents, as compared to DES. The "endothelial progenitor cell (EPC) capture stent" is an attractive concept, being strongly supported by the notion of "accelerated endothelial healing" in the present era of the "ESC firestorm." However, the clinical performance of EPC capture stents is far from satisfactory [<xref rid="B2-kjim-30-27" ref-type="bibr">2</xref>]. Such stents have not reduced the need for restenosis, and even stent safety has been challenged; reports of stent thrombosis have appeared. However, the concept of accelerated endothelial healing remains attractive.</p><p>Choi et al. [<xref rid="B3-kjim-30-27" ref-type="bibr">3</xref>], in an observational study, compared the effects of DES and EPC capture stents on microvascular dysfunction in post-percutaneous intervention (PCI) patients. The index of myocardial resistance (IMR) was significantly lower in the latter than in the former group 6 to 12 months after index PCI. IMR can be used to diagnose microvascular dysfunction [<xref rid="B4-kjim-30-27" ref-type="bibr">4</xref>], which is known to be associated with an increased risk of adverse cardiovascular events [<xref rid="B5-kjim-30-27" ref-type="bibr">5</xref>]. Previous studies on the effects of DES implantation on endothelial function have yielded mixed results. The effects of stent type on microvascular function have not been well-studied. EPC capture stents were associated with a lower IMR than were DES in the cited work, but the coronary flow reserve (CFR) did not differ between the two groups. Although the observed difference in IMR is interesting, any clinical implication of a lower IMR without any concomitant change in CFR in the EPC capture stent group remains unclear. The cited study was small and the patient groups heterogeneous. It is difficult to compare CFR and IMR between two small groups with mixed infarct- and non-infarct-related arterial lesions. Microvascular dysfunction is caused by multiple pathogenic mechanisms in patients with coronary artery disease, especially after coronary intervention [<xref rid="B5-kjim-30-27" ref-type="bibr">5</xref>]. No potential causal relationship between IMR and stent type can be inferred in the absence of baseline information that was not provided in the cited study. And paucity of data suporting clinical benefit of EPC capture stent compared with DES limit the clinical value of cited work. As the authors thereof indeed discussed, the study was observational in nature and had associated limitations. However, the efforts of the cited work to elucidate the biological differences between DES and EPC capture stents, using modern means of physiological evaluation, were valuable; the topic deserves further attention.</p></body><back><fn-group><fn fn-type="conflict"><p>No potential conflict of interest relevant to this article was reported.</p></fn></fn-group><ref-list><ref id="B1-kjim-30-27"><label>1</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Camenzind</surname><given-names>E</given-names></name><name><surname>Steg</surname><given-names>PG</given-names></name><name><surname>Wijns</surname><given-names>W</given-names></name></person-group><article-title>Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern</article-title><source>Circulation</source><year>2007</year><volume>115</volume><fpage>1440</fpage><lpage>1455</lpage><pub-id pub-id-type="pmid">17344324</pub-id></element-citation></ref><ref id="B2-kjim-30-27"><label>2</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Garg</surname><given-names>S</given-names></name><name><surname>Duckers</surname><given-names>HJ</given-names></name><name><surname>Serruys</surname><given-names>PW</given-names></name></person-group><article-title>Endothelial progenitor cell capture stents: will this technology find its niche in contemporary practice?</article-title><source>Eur Heart J</source><year>2010</year><volume>31</volume><fpage>1032</fpage><lpage>1035</lpage><pub-id pub-id-type="pmid">20064819</pub-id></element-citation></ref><ref id="B3-kjim-30-27"><label>3</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Choi</surname><given-names>WG</given-names></name><name><surname>Kim</surname><given-names>SH</given-names></name><name><surname>Yoon</surname><given-names>HS</given-names></name><name><surname>Lee</surname><given-names>EJ</given-names></name><name><surname>Kim</surname><given-names>DW</given-names></name></person-group><article-title>Impact of an endothelial progenitor cell capturing stent on coronary microvascular function: comparison with drug-eluting stents</article-title><source>Korean J Intern Med</source><year>2015</year><volume>30</volume><fpage>42</fpage><lpage>48</lpage></element-citation></ref><ref id="B4-kjim-30-27"><label>4</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Knaapen</surname><given-names>P</given-names></name><name><surname>Camici</surname><given-names>PG</given-names></name><name><surname>Marques</surname><given-names>KM</given-names></name><etal/></person-group><article-title>Coronary microvascular resistance: methods for its quantification in humans</article-title><source>Basic Res Cardiol</source><year>2009</year><volume>104</volume><fpage>485</fpage><lpage>498</lpage><pub-id pub-id-type="pmid">19468781</pub-id></element-citation></ref><ref id="B5-kjim-30-27"><label>5</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Crea</surname><given-names>F</given-names></name><name><surname>Camici</surname><given-names>PG</given-names></name><name><surname>Bairey Merz</surname><given-names>CN</given-names></name></person-group><article-title>Coronary microvascular dysfunction: an update</article-title><source>Eur Heart J</source><year>2014</year><volume>35</volume><fpage>1101</fpage><lpage>1111</lpage><pub-id pub-id-type="pmid">24366916</pub-id></element-citation></ref></ref-list></back></article>
