<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.0 20120330//EN" "JATS-journalpublishing1.dtd">
<article article-type="review-article" dtd-version="1.0" xml:lang="en" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">KJIM</journal-id>
<journal-title-group>
<journal-title>The Korean Journal of Internal Medicine</journal-title><abbrev-journal-title>Korean J Intern Med</abbrev-journal-title></journal-title-group>
<issn pub-type="ppub">1226-3303</issn>
<issn pub-type="epub">2005-6648</issn>
<publisher>
<publisher-name>The Korean Association of Internal Medicine</publisher-name></publisher></journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3904/kjim.2018.197</article-id>
<article-id pub-id-type="publisher-id">kjim-2018-197</article-id>
<article-categories>
<subj-group>
<subject>Review</subject></subj-group></article-categories>
<title-group>
<article-title>Clinical usefulness of bioimpedance analysis for assessing volume status in patients receiving maintenance dialysis</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Park</surname><given-names>Jung Hwan</given-names></name>
<xref ref-type="corresp" rid="c1-kjim-2018-197"/>
<xref ref-type="aff" rid="af1-kjim-2018-197"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Jo</surname><given-names>Young-Il</given-names></name>
<xref ref-type="aff" rid="af1-kjim-2018-197"/>
</contrib>
<contrib contrib-type="author">
<name><surname>Lee</surname><given-names>Jong-Ho</given-names></name>
<xref ref-type="aff" rid="af1-kjim-2018-197"/>
</contrib>
<aff id="af1-kjim-2018-197">
Division of Nephrology, Department of Internal Medicine, Konkuk University School of Medicine, Seoul, <country>Korea</country></aff>
</contrib-group>
<author-notes>
<corresp id="c1-kjim-2018-197">Correspondence to Jung Hwan Park, M.D. Division of Nephrology, Department of Internal Medicine, Konkuk University Medical Center, 120-1 Neungdong-ro, Gwangjin-gu, Seoul 05030, Korea Tel: +82-2-2030-7528 Fax: +82-2-2030-7748 E-mail: <email>pjh@kuh.ac.kr</email></corresp>
<fn id="fn1-kjim-2018-197"><p>This paper was contributed by Korean Society of Nephrology.</p></fn>
</author-notes>
<pub-date pub-type="ppub">
<month>7</month>
<year>2018</year></pub-date>
<pub-date pub-type="epub">
<day>28</day>
<month>6</month>
<year>2018</year></pub-date>
<volume>33</volume>
<issue>4</issue>
<fpage>660</fpage>
<lpage>669</lpage>
<history>
<date date-type="received">
<day>11</day>
<month>06</month>
<year>2018</year></date>
<date date-type="accepted">
<day>15</day>
<month>06</month>
<year>2018</year></date>
</history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2018 The Korean Association of Internal Medicine</copyright-statement>
<copyright-year>2018</copyright-year>
<license>
<license-p>This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (<ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/">http://creativecommons.org/licenses/by-nc/4.0/</ext-link>) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p></license></permissions>
<abstract><p>Chronic volume overload is associated with left ventricular hypertrophy and high cardiovascular mortality in patients undergoing dialysis. Therefore, estimating body fluid status is important in these patients. However, most dry-weight assessments are still performed clinically, while attempts have been made to measure the volume status and dry weight of patients undergoing dialysis using bioimpedance analysis (BIA). BIA uses the electrical properties of the human body to alternate current flow and measures resistance values to estimate body water content and composition. BIA is divided into single-frequency BIA, multi-frequency BIA, and bioimpedance spectroscopy (BIS) according to the number of frequencies used, and into whole-body and segmental BIA according to whether or not the whole body is divided into segments. Extracellular water (ECW), intracellular water, and total body water (TBW) contents can be measured with BIA. Dry weight can be estimated by measuring the volume overload of the patient through the ECW/TBW and ECW-to-body weight ratios. Other estimation methods include the normovolemia/hypervolemia slope method, a resistance-reactance (RXc) graph, overhydration measurements using a body composition monitor, and calf BIS. In this review, we will examine the principles of BIA, introduce various volume status measurement methods, and identify the optimal method for patients undergoing dialysis.</p></abstract>
<kwd-group>
<kwd>Bioimpedance analysis</kwd>
<kwd>Dialysis</kwd>
<kwd>Dry weight</kwd>
<kwd>Body composition monitor</kwd>
</kwd-group>
</article-meta></front>
<body>
<sec sec-type="intro">
<title>INTRODUCTION</title>
<p>The number of patients undergoing maintenance dialysis is increasing in Korea &#x0005b;<xref ref-type="bibr" rid="b1-kjim-2018-197">1</xref>&#x0005d;. Volume status is an important prognostic factor of these patients. Overhydration (OH) in patients undergoing dialysis is associated with the development of congestive heart failure and a higher frequency of mortality &#x0005b;<xref ref-type="bibr" rid="b2-kjim-2018-197">2</xref>-<xref ref-type="bibr" rid="b4-kjim-2018-197">4</xref>&#x0005d;. In contrast, dialysis-induced volume depletion and hypotension are common complications in patients undergoing hemodialysis (HD) and are independent risk factors for mortality &#x0005b;<xref ref-type="bibr" rid="b5-kjim-2018-197">5</xref>,<xref ref-type="bibr" rid="b6-kjim-2018-197">6</xref>&#x0005d;. Accurate assessment of volume status is required to manage volume, but this is a difficult task in patients undergoing dialysis. Clinical indices, such as blood pressure (BP), pulse rate, and edema, do not accurately reflect volume status. Some volume can remain in the body, and clinical edema may not be evident. Dry weight is defined as the weight at which a patient undergoing dialysis has neither edema nor hypertension without taking a BP-lowering medication, or the lowest weight that can be tolerated without developing symptoms of hypovolemia &#x0005b;<xref ref-type="bibr" rid="b7-kjim-2018-197">7</xref>,<xref ref-type="bibr" rid="b8-kjim-2018-197">8</xref>&#x0005d;. However, determining dry weight is a challenge for nephrologists because of the above-mentioned problems. Methods for determining dry weight have been suggested, including by reference to biochemical parameters, such as atrial or brain natriuretic peptide levels &#x0005b;<xref ref-type="bibr" rid="b9-kjim-2018-197">9</xref>&#x0005d;, inferior vena cava diameter on ultrasonography &#x0005b;<xref ref-type="bibr" rid="b10-kjim-2018-197">10</xref>&#x0005d;, and blood volume monitoring &#x0005b;<xref ref-type="bibr" rid="b11-kjim-2018-197">11</xref>&#x0005d;. However, dry weight estimates obtained using these methods are not accurate. Dilution methods, regarded as reference methods for measuring body fluid volumes, are as follows: deuterium for total body water (TBW) &#x0005b;<xref ref-type="bibr" rid="b12-kjim-2018-197">12</xref>&#x0005d;, bromide for extracellular water (ECW) &#x0005b;<xref ref-type="bibr" rid="b13-kjim-2018-197">13</xref>&#x0005d;, and radioactive potassium isotope (<sup>40</sup>K) for intracellular water (ICW) &#x0005b;<xref ref-type="bibr" rid="b14-kjim-2018-197">14</xref>&#x0005d;. Although these methods can be accurate, they are invasive, as they require blood samples, and are expensive due to the cost of the isotope and performance of mass spectrometry. Furthermore, they cannot be repeated at short intervals due to the retention of residual tracer, and they cannot be used to measure volume variations over a short period. Thus, bioimpedance analysis (BIA) is largely used instead, being a simple, noninvasive, and inexpensive method &#x0005b;<xref ref-type="bibr" rid="b15-kjim-2018-197">15</xref>&#x0005d;. TBW, ICW, and ECW can be measured using BIA &#x0005b;<xref ref-type="bibr" rid="b16-kjim-2018-197">16</xref>&#x0005d;. This method is precise and provides accurate estimates of TBW and ECW &#x0005b;<xref ref-type="bibr" rid="b17-kjim-2018-197">17</xref>&#x0005d;.</p></sec>
<sec>
<title>PRINCIPLES OF BIOELECTRICAL IMPEDANCE</title>
<p>BIA is based on the electrical properties of biological tissues &#x0005b;<xref ref-type="bibr" rid="b18-kjim-2018-197">18</xref>&#x0005d;. When sending a weak alternating electric current into the body, electricity flows along highly conductive body tissues &#x0005b;<xref ref-type="bibr" rid="b19-kjim-2018-197">19</xref>&#x0005d;. Current flows by two mechanisms: directly through the fluid and indirectly across cell membranes &#x0005b;<xref ref-type="bibr" rid="b20-kjim-2018-197">20</xref>&#x0005d;. Low frequency current does not pass through cells; instead, current flows through the extracellular fluid &#x0005b;<xref ref-type="bibr" rid="b21-kjim-2018-197">21</xref>&#x0005d;. However, the cell membrane capacitor charges and discharges the current at a high frequency. Thus, current flows through the cell membrane and tissue fluid (<xref rid="f1-kjim-2018-197" ref-type="fig">Fig. 1</xref>). The volume of water determines the width of the passage through which electricity flows, which is represented by impedance. Impedance (<italic>Z</italic>) is a force that interferes with the flow of electric current and is determined using the vector sum of the electrical resistance (<italic>R</italic>) and reactance (<italic>X<sub>c</sub></italic>). The component of impedance corresponding to flow through fluid is the resistance, and the component corresponding to flow across cell membranes is the reactance &#x0005b;<xref ref-type="bibr" rid="b22-kjim-2018-197">22</xref>&#x0005d;. However, in the human body, the difference between the impedance and resistance values is only about 2 to 3 &#x003a9; so the two words are often used interchangeably. The R of the length of the conductive material is proportional to its length and inversely proportional to its cross-sectional area &#x0005b;<xref ref-type="bibr" rid="b15-kjim-2018-197">15</xref>&#x0005d;.</p>
<disp-formula id="FD1">
<label>(1)</label>
<mml:math id="m1" display='block'>
<mml:mi>R</mml:mi><mml:mo>=</mml:mo><mml:mi>&#x3C1;</mml:mi><mml:mfrac><mml:mi>L</mml:mi><mml:mi>A</mml:mi></mml:mfrac></mml:math></disp-formula>
<disp-formula id="FD2">
<label>(2)</label>
<mml:math id="m2" display='block'><mml:mi>R</mml:mi><mml:mo>=</mml:mo><mml:mi>&#x3C1;</mml:mi><mml:mfrac><mml:mrow><mml:mi>L</mml:mi><mml:mo>&#xB7;</mml:mo><mml:mi>L</mml:mi></mml:mrow><mml:mrow><mml:mi>A</mml:mi><mml:mo>&#xB7;</mml:mo><mml:mi>L</mml:mi></mml:mrow></mml:mfrac><mml:mo>=</mml:mo><mml:mi>&#x3C1;</mml:mi><mml:mfrac><mml:msup><mml:mi>L</mml:mi><mml:mn>2</mml:mn></mml:msup><mml:mi>V</mml:mi></mml:mfrac></mml:math></disp-formula>
<disp-formula id="FD3">
<label>(3)</label>
<mml:math id="m3" display='block'><mml:mi>R</mml:mi><mml:mo>=</mml:mo><mml:mi>&#x3C1;</mml:mi><mml:mfrac><mml:msup><mml:mi>L</mml:mi><mml:mn>2</mml:mn></mml:msup><mml:mi>R</mml:mi></mml:mfrac></mml:math></disp-formula>
<p>Length (<italic>L</italic>) of the conductor is the length of the body, often replaced by the height. Resistivity (<italic>&#x003c1;</italic>) is the resistance value per unit volume of body water. It is assumed that the resistivity value is constant because a highly constant amount of electrolyte is dissolved per unit volume in body water.</p>
<disp-formula id="FD4">
<label>(4)</label>
<mml:math id="m4" display='block'><mml:mi>B</mml:mi><mml:mi>o</mml:mi><mml:mi>d</mml:mi><mml:mi>y</mml:mi><mml:mo>&#xA0;</mml:mo><mml:mi>w</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi><mml:mi>e</mml:mi><mml:mi>r</mml:mi><mml:mo>&#xA0;</mml:mo><mml:mi>v</mml:mi><mml:mi>o</mml:mi><mml:mi>l</mml:mi><mml:mi>m</mml:mi><mml:mi>e</mml:mi><mml:mo>&#xA0;</mml:mo><mml:mo>=</mml:mo><mml:mi>C</mml:mi><mml:mo>&#xD7;</mml:mo><mml:mfrac><mml:mrow><mml:mi>h</mml:mi><mml:mi>e</mml:mi><mml:mi>i</mml:mi><mml:mi>g</mml:mi><mml:mi>h</mml:mi><mml:msup><mml:mi>t</mml:mi><mml:mn>2</mml:mn></mml:msup></mml:mrow><mml:mi>R</mml:mi></mml:mfrac></mml:math></disp-formula>
<p>To measure impedance of the body, electrodes are attached to the right wrist, back of the hand, right ankle, and foot, as shown in <xref rid="f2-kjim-2018-197" ref-type="fig">Fig. 2</xref>, and connected to the impedance meter. The impedance meter supplies a current of 50 kHz and 800 &#x003bc;A between the electrodes of the back of the hand and the foot. Current flows through the right arm, torso, and right leg, where the impedance meter measures the voltage between the wrist and the ankle.</p>
<p>With the given current value and the measured voltage, the electric resistance value is obtained using Ohm&#x02019;s law.</p>
<disp-formula id="FD5">
<label>(5)</label>
<mml:math id="m5" display='block'><mml:mi>R</mml:mi><mml:mo>=</mml:mo><mml:mfrac><mml:mi>V</mml:mi><mml:mi>i</mml:mi></mml:mfrac></mml:math></disp-formula>
<p>After the height is measured, body water can be obtained by substituting the obtained resistance value of the body into (4).</p>
</sec>
<sec>
<title>SINGLE-FREQUENCY BIA</title>
<p>BIA information obtained at an electric current of 50 KHz is known as single-frequency BIA (SF-BIA). SF-BIA is the earliest and most frequently used methods to estimate the volume of body compartments &#x0005b;<xref ref-type="bibr" rid="b23-kjim-2018-197">23</xref>&#x0005d;. SF-BIA predicts the volume of the TBW. However, strictly speaking, it does not measure TBW volume but rather the weighted sum of the ECW and ICW resistivities &#x0005b;<xref ref-type="bibr" rid="b15-kjim-2018-197">15</xref>&#x0005d;. SF-BIA permits assessment of TBW and fat-free mass (FFM) for normal hydrated persons but is not appropriate under conditions of significantly altered hydration &#x0005b;<xref ref-type="bibr" rid="b24-kjim-2018-197">24</xref>&#x0005d;.</p>
</sec>
<sec>
<title>MULTIPLE-FREQUENCY BIA</title>
<p>Multiple-frequency BIA (MF-BIA) is a technology that precisely measures body water content, by measuring body water separately from ICW and ECW. Human impedance measured using high-frequency electrical signals reflects ICW and ECW, while low-frequency signals reflect only ECW. MF-BIA measures the distribution of water inside and outside the cell, by changing the frequency to in turn change the flow path of electricity. MF-BIA uses different frequencies (5 to 1,000 kHz) to evaluate FFM, TBW, ICW, and ECW. Hannan et al. &#x0005b;<xref ref-type="bibr" rid="b25-kjim-2018-197">25</xref>&#x0005d; reported that TBW volume is more accurately estimated using MF-BIA than using the bioimpedance spectroscopy (BIS) method, which estimates ECW volume with equal accuracy. Patel et al. &#x0005b;<xref ref-type="bibr" rid="b26-kjim-2018-197">26</xref>&#x0005d; reported that MFBIA was more accurate than SF-BIA for predicting ECW, whereas SF-BIA was more accurate for predicting TBW than MF-BIA in diseased subjects. MF-BIA shows less sensitivity in detecting fluid shifts between the ECW and the ICW in elderly patients &#x0005b;<xref ref-type="bibr" rid="b27-kjim-2018-197">27</xref>&#x0005d;.</p>
</sec>
<sec>
<title>BIOIMPEDANCE SPECTROSCOPY</title>
<p>BIS analyzes bioimpedance data obtained using a broadband of frequencies. The BIS method is based on determining resistance at zero and infinite frequencies, which are then used to predict ECW and TBW, respectively &#x0005b;<xref ref-type="bibr" rid="b23-kjim-2018-197">23</xref>&#x0005d;.</p>
</sec>
<sec>
<title>WHOLE-BODY BIA</title>
<p>Whole-body BIA regards the body as a cylinder having a certain length and cross-sectional area &#x0005b;<xref ref-type="bibr" rid="b18-kjim-2018-197">18</xref>&#x0005d;. Its limitation is that it assumes that a body with arms, a trunk, and legs constitutes a single cylinder having uniform conductivity for any given cross-sectional area. The resistance to volume ratio differs between the trunk and the limbs. Limbs contribute &gt; 90% of whole-body resistance despite having only 30% of the total volume, whereas the trunk, with a large cross-sectional area, contributes as little as 10% of whole-body resistance with 70% of the volume &#x0005b;<xref ref-type="bibr" rid="b28-kjim-2018-197">28</xref>&#x0005d;.</p>
</sec>
<sec>
<title>SEGMENTAL BIA</title>
<p>Segmental BIA has been developed to overcome the limitations of whole-body BIA. It regards the body as comprising five cylinders: two for the arms, two for the legs, and one for the trunk &#x0005b;<xref ref-type="bibr" rid="b18-kjim-2018-197">18</xref>&#x0005d;. The device used to measure segmental BIA herein has up to eight electrodes (InBody, Seoul, Korea); two electrodes are in contact with the palm (E1, E3) and thumb (E2, E4) of each hand; and two are in contact with the anterior (E5, E7) and posterior aspects (E6, E8) of the sole of each foot (<xref rid="f3-kjim-2018-197" ref-type="fig">Fig. 3</xref>) &#x0005b;<xref ref-type="bibr" rid="b29-kjim-2018-197">29</xref>&#x0005d;. The electrical resistance values of the right arm, left arm, trunk, right leg, and left leg are indicated by <italic>R</italic><sub>RA</sub>, <italic>R</italic><sub>LA</sub>, <italic>R</italic><sub>T</sub>, <italic>R</italic><sub>RL</sub>, and <italic>R</italic><sub>LL</sub>, respectively. An alternating current of intensity (<italic>I</italic>) is applied between E1 and E5. The voltage difference (<italic>V</italic>) between E2 and E4 is divided by <italic>I</italic> to obtain the resistance of the right arm. The current flows through <italic>R</italic><sub>1</sub>-<italic>R</italic><sub>RA</sub>-<italic>R</italic><sub>T</sub>-<italic>R</italic><sub>3</sub>, and the voltage is measured in a loop formed by <italic>R</italic><sub>2</sub>-<italic>R</italic><sub>RA</sub>-<italic>R</italic><sub>LA</sub>-<italic>R</italic><sub>2</sub>. The loop in which the current flows and the voltage measured overlap in <italic>R</italic><sub>RA</sub> to measure resistance of the right arm &#x0005b;<xref ref-type="bibr" rid="b19-kjim-2018-197">19</xref>&#x0005d;. Segmental BIA has been used to determine fluid shifts and distributions in certain conditions, such as ascites and kidney disease, as well as during surgery &#x0005b;<xref ref-type="bibr" rid="b15-kjim-2018-197">15</xref>&#x0005d;.</p>
</sec>
<sec>
<title>ASSESSMENT OF FLUID OVERLOAD WITH BIA</title>
<p>The normovolemic status of a subject can be estimated according to measurements of height, weight, and the body composition, as assessed by BIA. Fluid overload is calculated by subtracting the fluid volume according to the normovolemic status from that measured by BIA &#x0005b;<xref ref-type="bibr" rid="b30-kjim-2018-197">30</xref>,<xref ref-type="bibr" rid="b31-kjim-2018-197">31</xref>&#x0005d;. Several methods can be used to estimate fluid overload by BIA. Chamney et al. &#x0005b;<xref ref-type="bibr" rid="b30-kjim-2018-197">30</xref>&#x0005d; used whole-body BIA to differentiate hypervolemia from normovolemia. A 70-kg healthy person has an ECW volume of 14 to 16 L &#x0005b;<xref ref-type="bibr" rid="b32-kjim-2018-197">32</xref>&#x0005d;. They assumed that a linear relationship exists between ECW and body weight. The slope of this relationship has been denoted by the slope of normovolemia (S<sub>NV</sub>) (<xref rid="f4-kjim-2018-197" ref-type="fig">Fig. 4</xref>). S<sub>NV</sub> represents the average ECW volume for a given weight. All ingested fluid accumulates in the body and body weight increases in a patient undergoing dialysis. A second slope, the hypervolemic slope (S<sub>HV</sub>), also develops under this hypervolemic condition.</p>
<p>Deducing the hydration status of a patient from the absolute body fluid volume alone is not appropriate because absolute water volume varies with height, weight, and body composition &#x0005b;<xref ref-type="bibr" rid="b33-kjim-2018-197">33</xref>&#x0005d;. As an alternative, fluid compartment ratios, as indicators of hydration status, have been used including the ratio of ECW to TBW &#x0005b;<xref ref-type="bibr" rid="b34-kjim-2018-197">34</xref>,<xref ref-type="bibr" rid="b35-kjim-2018-197">35</xref>&#x0005d;. This ratio is easy to use, intuitive, and well validated as a predictor of survival &#x0005b;<xref ref-type="bibr" rid="b36-kjim-2018-197">36</xref>&#x0005d;. However, the standard deviation of this ratio is so large that its use is impracticable &#x0005b;<xref ref-type="bibr" rid="b33-kjim-2018-197">33</xref>&#x0005d;. Ratios that have been used by other researchers include ECW to body weight &#x0005b;<xref ref-type="bibr" rid="b37-kjim-2018-197">37</xref>,<xref ref-type="bibr" rid="b38-kjim-2018-197">38</xref>&#x0005d;, ECW to body height &#x0005b;<xref ref-type="bibr" rid="b38-kjim-2018-197">38</xref>,<xref ref-type="bibr" rid="b39-kjim-2018-197">39</xref>&#x0005d;, and ECW to body surface area &#x0005b;<xref ref-type="bibr" rid="b40-kjim-2018-197">40</xref>&#x0005d;.</p>
<p>The resistance-reactance (RXc) graph method uses a direct impedance vector measurement (given by R and <italic>Xc</italic>) at 50 kHz with whole-body SF-BIA &#x0005b;<xref ref-type="bibr" rid="b41-kjim-2018-197">41</xref>&#x0005d;. R and <italic>Xc</italic> are plotted against each other and normalized by height. The <italic>R/H</italic> and <italic>Xc/H</italic> (&#x003a9;/m) ratios of a given patient are plotted on the RXc plane (<xref rid="f5-kjim-2018-197" ref-type="fig">Fig. 5</xref>). The vector length represents the size of the impedance. Clinical information on hydration is obtained by determining the location of the vector point for a normally hydrated healthy individual of the same sex, age, and race &#x0005b;<xref ref-type="bibr" rid="b42-kjim-2018-197">42</xref>&#x0005d;. Vectors within the 75% tolerance ellipse indicate normal hydration status.</p>
<p>A body composition monitor (BCM, Fresenius Medical Care, Bad Homburg, Germany) is used to measure OH. It uses two physiological models: in the volume model, the ECW and ICW are calculated using the resistance values measured with the BCM and Hanai model &#x0005b;<xref ref-type="bibr" rid="b31-kjim-2018-197">31</xref>&#x0005d;; while in the body composition model, TBW is divided into three parts, i.e., OH, lean tissue, and adipose tissue (<xref rid="f6-kjim-2018-197" ref-type="fig">Fig. 6</xref>) &#x0005b;<xref ref-type="bibr" rid="b43-kjim-2018-197">43</xref>,<xref ref-type="bibr" rid="b44-kjim-2018-197">44</xref>&#x0005d;. Absolute fluid overload (AFO; equivalent to OH) is defined as the difference between the expected ECW under normal physiological conditions and the actual ECW, while relative fluid overload (RFO) is the AFO as a proportion of ECW (AFO/ECW) &#x0005b;<xref ref-type="bibr" rid="b45-kjim-2018-197">45</xref>&#x0005d;. All calculations are performed automatically using BCM software. Normohydration is defined when the AFO is in the 10th to 90th percentile range; that is, &#x02013;1.1 to 1.1 L relative to healthy age- and sex-matched individuals from the reference group. Volumes below and above this range are defined as underhydration and OH, respectively.</p>
</sec>
<sec>
<title>DRY WEIGHT ASSESSMENT BY BIA</title>
<p>The normovolemia/hypervolemia slope method predicts dry weight from the BIS measurement and body weight (<xref rid="f4-kjim-2018-197" ref-type="fig">Fig. 4</xref>) &#x0005b;<xref ref-type="bibr" rid="b18-kjim-2018-197">18</xref>,<xref ref-type="bibr" rid="b30-kjim-2018-197">30</xref>&#x0005d;. All fluid is assumed to accumulate in the ECW. If the weight of a hypervolemic patient is reduced and S<sub>HV</sub> intersects with S<sub>NV</sub>, the weight at which intersection occurs is the dry weight. In a study by Chamney et al. &#x0005b;<xref ref-type="bibr" rid="b30-kjim-2018-197">30</xref>&#x0005d;, the dialyzed weight of each patient typically decreased between 0.5 and 2 kg over subsequent dialyses and most patients achieve normovolemia in 2 to 6 weeks. A considerable improvement in BP control was achieved in that study, based on the mean arterial pressure, and there was an 86% reduction in the use of antihypertensive medication.</p>
<p>Chen et al. &#x0005b;<xref ref-type="bibr" rid="b46-kjim-2018-197">46</xref>&#x0005d; used ECW% (ECW as a percentage of weight) to determine the dry weight. ECW was measured by whole-body BIA. An ECW% &gt; 25% in female patients and &gt; 28% in male patients was considered excessive according to the 100th percentile of healthy subjects. The ECW% of patients with a high BP was significantly higher than that of patients with a normal BP (24.29% &#x000b1; 3.56% vs. 21.50% &#x000b1; 2.38%). All patients with an excessive ECW% had high BPs, but not all patients with high BPs had an excessive ECW%. No patient with a normal BP had an excessive ECW%. Dry weight decreased in patients with a high BP and excessive ECW%. ECW% and BP decreased significantly after reducing dry weight. Dry weight increased in the symptomatic normotensive patients and symptoms improved in most of these patients (75%).</p>
<p>The vector length in the RXc graph is regarded as a proxy for volume status and increases with ultrafiltration. Shorter predialysis bioimpedance vectors, indicating OH, are associated with an increased mortality risk in patients undergoing HD &#x0005b;<xref ref-type="bibr" rid="b47-kjim-2018-197">47</xref>&#x0005d;. Vectors situated within the 75% tolerance ellipse after ultrafiltration are assumed to indicate normal hydration in patients undergoing HD. However, vectors at the start and end of HD remain within the 75% tolerance ellipse in a relatively large proportion of patients &#x0005b;<xref ref-type="bibr" rid="b48-kjim-2018-197">48</xref>&#x0005d;.</p>
<p>Onofriescu et al. &#x0005b;<xref ref-type="bibr" rid="b45-kjim-2018-197">45</xref>&#x0005d; used BCM to determine dry weight. They compared a bioimpedance group (volume controlled based on repeated BCM measurement in a 3-month period) with a clinical group over 2.5 years. RFO decreased significantly, from 9.52% to 7.46%, in the bioimpedance group, whereas RFO did not decrease (10.30% to 11.24%) in the clinical group. Systolic BP decreased significantly, from 145.4 to 138.9 mmHg, in the bioimpedance group, whereas systolic BP decreased from 144.6 to 140.5 mmHg in the clinical group; the decrease was not significant. In another study, these authors also reported that the cutoff RFO of 17.4% was associated with an increased risk of all-cause mortality in patients undergoing HD &#x0005b;<xref ref-type="bibr" rid="b49-kjim-2018-197">49</xref>&#x0005d;.</p>
<p>Machek et al. &#x0005b;<xref ref-type="bibr" rid="b50-kjim-2018-197">50</xref>&#x0005d; conducted a study to determine the normohydration status of patients undergoing HD using BCM. The patients were categorized according to baseline hydration status, as follows: hyperhydrated group (RFO &gt; 15%); adverse event group (patients with more than two adverse events in the last 4 weeks); and all other patients. They targeted an RFO value of between &#x02013;6% and 6% postdialysis. Fluid overload was reduced by 2.0 L in the hyperhydrated group without increasing the number of intradialytic adverse events. Systolic BP was reduced by 25 mmHg, and a 35% reduction in antihypertensive medication use was achieved. Volume status was increased by 1.3 L in the adverse event group, and a 73% reduction in intradialytic adverse events was achieved without a significant increase in BP.</p>
<p>Moissl et al. &#x0005b;<xref ref-type="bibr" rid="b51-kjim-2018-197">51</xref>&#x0005d; introduced the concept of weekly time-averaged fluid overload (TAFO), defined as the average of three predialysis fluid overload (FOpre) and postdialysis fluid overload (FOpost) values in a week, as follows: average weekly TAFO &#x0003d; (FOpre1 &#x0002b; FOpre2 &#x0002b; FOpre3 &#x0002b; FOpost1 &#x0002b; FOpost2 &#x0002b; FOpost3) / 6.</p>
<p>They used a target TAFO of 0.5 L, according to the median value of more than 17,000 patients. They measured BCM on 3 days per week on which dialysis was performed. At the end of each week, the postdialysis target weights for the next week were calculated according to the following criteria:</p>
<p>(1) TAFO &gt; 2.8 L: decrease postdialysis weight by 1 kg/week</p>
<p>(2) TAFO between 1.25 and 2.8 L: decrease postdialysis weight by 0.5 kg/week</p>
<p>(3) TAFO between &#x02013;0.25 and 1.25 L (on target): maintain current dry weight</p>
<p>(4) TAFO &lt; &#x02013;0.25 L: increase postdialysis weight by 0.5 kg/week</p>
<p>The TAFO of all patients decreased from 0.9 &#x000b1; 1.6 to 0.6 &#x000b1; 1.1 L. TAFO decreased by &#x02013;1.20 &#x000b1; 1.32 L in the fluid overload group (baseline TAFO &gt; 1.25 L above the target) and was unchanged in the normovolemic group (baseline TAFO between &#x02013;0.25 and 1.25), but increased by 0.59 &#x000b1; 0.76 L in the underhydrated group (baseline TAFO &lt; &#x02013;0.25 L). Every 1-L change in fluid overload was accompanied by a 9.9-mmHg/L change in the predialysis systolic BP. The number of intradialytic adverse events did not change significantly in any of the groups.</p>
<p>The calf-BIS method has been proposed as a method of measuring dry body weight. This is useful because the calf-ECW reflects whole-body ECW &#x0005b;<xref ref-type="bibr" rid="b52-kjim-2018-197">52</xref>&#x0005d;. Calf-BIS is continuously measured during HD to identify the section wherein the <italic>R</italic><sub>0</sub>/<italic>R</italic><sub>t</sub> curve becomes flat (<italic>R</italic><sub>0</sub> is the calf extracellular resistance at the HD start time, and <italic>R</italic><sub>t</sub> is the calf extracellular resistance at a specific time point) (<xref rid="f7-kjim-2018-197" ref-type="fig">Fig. 7</xref>). In this section, all excess ECW fluid was removed, and the weight was considered dry weight.</p>
</sec>
<sec>
<title>BIA IN PATIENTS UNDERGOING PERITONEAL DIALYSIS</title>
<p>Many patients undergoing peritoneal dialysis (PD) are in a state of OH &#x0005b;<xref ref-type="bibr" rid="b37-kjim-2018-197">37</xref>,<xref ref-type="bibr" rid="b53-kjim-2018-197">53</xref>&#x0005d;. In patients undergoing PD, who lack the signs of dehydration observed in patients undergoing HD (such as hypotension or cramps during dialysis), it is more difficult to determine dry weight than in patients undergoing HD &#x0005b;<xref ref-type="bibr" rid="b33-kjim-2018-197">33</xref>&#x0005d;. BIA is also a noninvasive, inexpensive, and simple way to measure body fluid in patients undergoing PD.</p>
<p>Lindley et al. &#x0005b;<xref ref-type="bibr" rid="b35-kjim-2018-197">35</xref>&#x0005d; used BIS to estimate volume status in 31 patients undergoing PD and 199 healthy subjects. The ECW/TBW ratio of the patients undergoing PD was compared with that of healthy control subjects. The hydration score (difference between the measured ECW/TBW ratio and the mean ratio for age- and sexmatched controls divided by the standard deviation of the controls) was calculated. The mean hydration score was significantly higher (1.3 vs. 0.0) in the patients undergoing PD than in the control subjects. In total, 35% of the patients undergoing PD, and only 2.5% of the controls, had a hydration score &gt; 2.0. After a 3-month follow-up, a weight reduction of 3.6 &#x000b1; 2.3 kg had been achieved in seven patients through modality or prescription changes, with no adverse effects.</p>
<p>van de Kerkhof et al. &#x0005b;<xref ref-type="bibr" rid="b38-kjim-2018-197">38</xref>&#x0005d; used MF-BIA to validate the predictive value of various ratios for diagnosing hypervolemia in patients undergoing dialysis. They divided the patients into the following groups: clinically normovolemic (mean 24- or 48-hour systolic BP &lt; 133 mmHg without antihypertensive agents), hypervolemic (mean systolic BP &gt; 133 mmHg with use of two or more antihypertensive agents), or undetermined. The 80th percentile for normalized ECW in the clinically normovolemic patients was used as the reference value. The ECW/body height ratio had a higher sensitivity than the ECW/body weight ratio or ECW/TBW ratio for detecting hypervolemia in patients undergoing dialysis.</p>
<p>O&#x02019;Lone et al. &#x0005b;<xref ref-type="bibr" rid="b54-kjim-2018-197">54</xref>&#x0005d; showed that the OH/ECW ratio was an independent predictor of mortality in 529 patients undergoing PD, but the ECW/TBW ratio was not associated with increased mortality. Yoon et al. &#x0005b;<xref ref-type="bibr" rid="b55-kjim-2018-197">55</xref>&#x0005d; reported that OH was associated with lower health-related quality of life in 481 patients undergoing PD.</p>
<p>A recent study suggested that the ratio of bioimpedance (RBI) might be a helpful parameter to adjust dry weight in patients undergoing PD &#x0005b;<xref ref-type="bibr" rid="b56-kjim-2018-197">56</xref>&#x0005d;. RBI was calculated as follows: RBI &#x0003d; impedance at 50 kHz / impedance at 500 kHz. RBI was measured from the right wrist to the right ankle by BCM. The patients were divided into hypervolemic and non-hypervolemic groups. The mean RBI of the non-hypervolemic patients was higher than that of the hypervolemic patients. They concluded that RBI could serve as a new index for estimating the volume status of patients undergoing PD.</p>
</sec>
<sec sec-type="Conclusions">
<title>CONCLUSIONS</title>
<p>Various BIA devices are increasingly being used in clinical practice, such as for estimating dry weight in patients undergoing dialysis. In patients undergoing HD or PD, volume overload commonly occurs, and identifying and reducing volume overload with BIA devices improves the prognosis by decreasing the BP and left ventricular hypertrophy &#x0005b;<xref ref-type="bibr" rid="b51-kjim-2018-197">51</xref>,<xref ref-type="bibr" rid="b57-kjim-2018-197">57</xref>-<xref ref-type="bibr" rid="b60-kjim-2018-197">60</xref>&#x0005d;. In addition, adverse events can be decreased in patients with a depleted volume by detecting their volume status and increasing the dry weight. However, the accuracy of OH measurement is the most important consideration.</p>
<p>The normovolemia/hypervolemia slope method is a useful method for determining dry weight, and reducing the variation in S<sub>NV</sub> is key to its accuracy. Ratio values, such as ECW%, are intuitive and easy to use, but both values can be abnormal because it is a ratio. The RXc graph has the advantage of yielding a relatively simple dry weight prediction without the need to measure volume status. However, as described earlier, it is sometimes difficult to determine dry weight because the vector can be within the 75% tolerance ellipse at the beginning and end of the dialysis. The calf-BIS method allows continuous monitoring during dialysis and provides relatively accurate data on hydration status, although measuring calf circumference is laborious. BCM methods are currently the most widely used and have been validated in various ways.</p>
<p>In conclusion, BIA is a useful method for controlling volume in patients undergoing dialysis, but more research is needed to establish a standard method.</p>
</sec>
</body>
<back>
<fn-group>
<fn fn-type="conflict"><p>No potential conflict of interest relevant to this article was reported.</p></fn>
</fn-group>
<ack><p>This manuscript was written as part of Konkuk University’s research support program for its faculty on sabbatical leave in 2010.</p></ack>
<ref-list>
<title>REFERENCES</title>
<ref id="b1-kjim-2018-197">
<label>1</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Jin</surname><given-names>DC</given-names></name>
<name><surname>Yun</surname><given-names>SR</given-names></name>
<name><surname>Lee</surname><given-names>SW</given-names></name>
<name><surname>Han</surname><given-names>SW</given-names></name>
<name><surname>Kim</surname><given-names>W</given-names></name>
<name><surname>Park</surname><given-names>J</given-names></name>
</person-group>
<article-title>Current characteristics of dialysis therapy in Korea: 2015 registry data focusing on elderly patients</article-title>
<source>Kidney Res Clin Pract</source>
<year>2016</year>
<volume>35</volume>
<fpage>204</fpage>
<lpage>211</lpage>
</element-citation></ref>
<ref id="b2-kjim-2018-197">
<label>2</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Parfrey</surname><given-names>PS</given-names></name>
<name><surname>Harnett</surname><given-names>JD</given-names></name>
<name><surname>Griffiths</surname><given-names>SM</given-names></name>
<name><surname>Gault</surname><given-names>MH</given-names></name>
<name><surname>Barre</surname><given-names>PE</given-names></name>
</person-group>
<article-title>Congestive heart failure in dialysis patients</article-title>
<source>Arch Intern Med</source>
<year>1988</year>
<volume>148</volume>
<fpage>1519</fpage>
<lpage>1525</lpage>
</element-citation></ref>
<ref id="b3-kjim-2018-197">
<label>3</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Wizemann</surname><given-names>V</given-names></name>
<name><surname>Wabel</surname><given-names>P</given-names></name>
<name><surname>Chamney</surname><given-names>P</given-names></name>
<etal/>
</person-group>
<article-title>The mortality risk of overhydration in haemodialysis patients</article-title>
<source>Nephrol Dial Transplant</source>
<year>2009</year>
<volume>24</volume>
<fpage>1574</fpage>
<lpage>1579</lpage>
</element-citation></ref>
<ref id="b4-kjim-2018-197">
<label>4</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Kim</surname><given-names>YJ</given-names></name>
<name><surname>Jeon</surname><given-names>HJ</given-names></name>
<name><surname>Kim</surname><given-names>YH</given-names></name>
<etal/>
</person-group>
<article-title>Overhydration measured by bioimpedance analysis and the survival of patients on maintenance hemodialysis: a single-center study</article-title>
<source>Kidney Res Clin Pract</source>
<year>2015</year>
<volume>34</volume>
<fpage>212</fpage>
<lpage>218</lpage>
</element-citation></ref>
<ref id="b5-kjim-2018-197">
<label>5</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Barth</surname><given-names>C</given-names></name>
<name><surname>Boer</surname><given-names>W</given-names></name>
<name><surname>Garzoni</surname><given-names>D</given-names></name>
<etal/>
</person-group>
<article-title>Characteristics of hypotension-prone haemodialysis patients: is there a critical relative blood volume?</article-title>
<source>Nephrol Dial Transplant</source>
<year>2003</year>
<volume>18</volume>
<fpage>1353</fpage>
<lpage>1360</lpage>
</element-citation></ref>
<ref id="b6-kjim-2018-197">
<label>6</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Shoji</surname><given-names>T</given-names></name>
<name><surname>Tsubakihara</surname><given-names>Y</given-names></name>
<name><surname>Fujii</surname><given-names>M</given-names></name>
<name><surname>Imai</surname><given-names>E</given-names></name>
</person-group>
<article-title>Hemodialysis-associated hypotension as an independent risk factor for two-year mortality in hemodialysis patients</article-title>
<source>Kidney Int</source>
<year>2004</year>
<volume>66</volume>
<fpage>1212</fpage>
<lpage>1220</lpage>
</element-citation></ref>
<ref id="b7-kjim-2018-197">
<label>7</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Thomson</surname><given-names>GE</given-names></name>
<name><surname>Waterhouse</surname><given-names>K</given-names></name>
<name><surname>McDonald</surname><given-names>HP</given-names><suffix>Jr</suffix></name>
<name><surname>Friedman</surname><given-names>EA</given-names></name>
</person-group>
<article-title>Hemodialysis for chronic renal failure. Clinical observations</article-title>
<source>Arch Intern Med</source>
<year>1967</year>
<volume>120</volume>
<fpage>153</fpage>
<lpage>167</lpage>
</element-citation></ref>
<ref id="b8-kjim-2018-197">
<label>8</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Vasko</surname><given-names>R</given-names></name>
<name><surname>Muller</surname><given-names>GA</given-names></name>
<name><surname>Ratliff</surname><given-names>BB</given-names></name>
<name><surname>Jung</surname><given-names>K</given-names></name>
<name><surname>Gauczinski</surname><given-names>S</given-names></name>
<name><surname>Koziolek</surname><given-names>MJ</given-names></name>
</person-group>
<article-title>Clinical judgment is the most important element in overhydration assessment of chronic hemodialysis patients</article-title>
<source>Clin Exp Nephrol</source>
<year>2013</year>
<volume>17</volume>
<fpage>563</fpage>
<lpage>568</lpage>
</element-citation></ref>
<ref id="b9-kjim-2018-197">
<label>9</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Lee</surname><given-names>SW</given-names></name>
<name><surname>Song</surname><given-names>JH</given-names></name>
<name><surname>Kim</surname><given-names>GA</given-names></name>
<name><surname>Lim</surname><given-names>HJ</given-names></name>
<name><surname>Kim</surname><given-names>MJ</given-names></name>
</person-group>
<article-title>Plasma brain natriuretic peptide concentration on assessment of hydration status in hemodialysis patient</article-title>
<source>Am J Kidney Dis</source>
<year>2003</year>
<volume>41</volume>
<fpage>1257</fpage>
<lpage>1266</lpage>
</element-citation></ref>
<ref id="b10-kjim-2018-197">
<label>10</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Ando</surname><given-names>Y</given-names></name>
<name><surname>Yanagiba</surname><given-names>S</given-names></name>
<name><surname>Asano</surname><given-names>Y</given-names></name>
</person-group>
<article-title>The inferior vena cava diameter as a marker of dry weight in chronic hemodialyzed patients</article-title>
<source>Artif Organs</source>
<year>1995</year>
<volume>19</volume>
<fpage>1237</fpage>
<lpage>1242</lpage>
</element-citation></ref>
<ref id="b11-kjim-2018-197">
<label>11</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Steuer</surname><given-names>RR</given-names></name>
<name><surname>Germain</surname><given-names>MJ</given-names></name>
<name><surname>Leypoldt</surname><given-names>JK</given-names></name>
<name><surname>Cheung</surname><given-names>AK</given-names></name>
</person-group>
<article-title>Enhanced fluid removal guided by blood volume monitoring during chronic hemodialysis</article-title>
<source>Artif Organs</source>
<year>1998</year>
<volume>22</volume>
<fpage>627</fpage>
<lpage>632</lpage>
</element-citation></ref>
<ref id="b12-kjim-2018-197">
<label>12</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Schloerb</surname><given-names>PR</given-names></name>
<name><surname>Friis-hansen</surname><given-names>BJ</given-names></name>
<name><surname>Edelman</surname><given-names>IS</given-names></name>
<name><surname>Solomon</surname><given-names>AK</given-names></name>
<name><surname>Moore</surname><given-names>FD</given-names></name>
</person-group>
<article-title>The measurement of total body water in the human subject by deuterium oxide dilution; with a consideration of the dynamics of deuterium distribution</article-title>
<source>J Clin Invest</source>
<year>1950</year>
<volume>29</volume>
<fpage>1296</fpage>
<lpage>1310</lpage>
</element-citation></ref>
<ref id="b13-kjim-2018-197">
<label>13</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Miller</surname><given-names>ME</given-names></name>
<name><surname>Cosgriff</surname><given-names>JM</given-names></name>
<name><surname>Forbes</surname><given-names>GB</given-names></name>
</person-group>
<article-title>Bromide space determination using anion-exchange chromatography for measurement of bromide</article-title>
<source>Am J Clin Nutr</source>
<year>1989</year>
<volume>50</volume>
<fpage>168</fpage>
<lpage>171</lpage>
</element-citation></ref>
<ref id="b14-kjim-2018-197">
<label>14</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Pierson</surname><given-names>RN</given-names><suffix>Jr</suffix></name>
<name><surname>Wang</surname><given-names>J</given-names></name>
<name><surname>Colt</surname><given-names>EW</given-names></name>
<name><surname>Neumann</surname><given-names>P</given-names></name>
</person-group>
<article-title>Body composition measurements in normal man: the potassium, sodium, sulfate and tritium spaces in 58 adults</article-title>
<source>J Chronic Dis</source>
<year>1982</year>
<volume>35</volume>
<fpage>419</fpage>
<lpage>428</lpage>
</element-citation></ref>
<ref id="b15-kjim-2018-197">
<label>15</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Kyle</surname><given-names>UG</given-names></name>
<name><surname>Bosaeus</surname><given-names>I</given-names></name>
<name><surname>De Lorenzo</surname><given-names>AD</given-names></name>
<etal/>
</person-group>
<article-title>Bioelectrical impedance analysis: part I: review of principles and methods</article-title>
<source>Clin Nutr</source>
<year>2004</year>
<volume>23</volume>
<fpage>1226</fpage>
<lpage>1243</lpage>
</element-citation></ref>
<ref id="b16-kjim-2018-197">
<label>16</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Hannan</surname><given-names>WJ</given-names></name>
<name><surname>Cowen</surname><given-names>SJ</given-names></name>
<name><surname>Fearon</surname><given-names>KC</given-names></name>
<name><surname>Plester</surname><given-names>CE</given-names></name>
<name><surname>Falconer</surname><given-names>JS</given-names></name>
<name><surname>Richardson</surname><given-names>RA</given-names></name>
</person-group>
<article-title>Evaluation of multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients</article-title>
<source>Clin Sci (Lond)</source>
<year>1994</year>
<volume>86</volume>
<fpage>479</fpage>
<lpage>485</lpage>
</element-citation></ref>
<ref id="b17-kjim-2018-197">
<label>17</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Sartorio</surname><given-names>A</given-names></name>
<name><surname>Malavolti</surname><given-names>M</given-names></name>
<name><surname>Agosti</surname><given-names>F</given-names></name>
<etal/>
</person-group>
<article-title>Body water distribution in severe obesity and its assessment from eight-polar bioelectrical impedance analysis</article-title>
<source>Eur J Clin Nutr</source>
<year>2005</year>
<volume>59</volume>
<fpage>155</fpage>
<lpage>160</lpage>
</element-citation></ref>
<ref id="b18-kjim-2018-197">
<label>18</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Kuhlmann</surname><given-names>MK</given-names></name>
<name><surname>Zhu</surname><given-names>F</given-names></name>
<name><surname>Seibert</surname><given-names>E</given-names></name>
<name><surname>Levin</surname><given-names>NW</given-names></name>
</person-group>
<article-title>Bioimpedance, dry weight and blood pressure control: new methods and consequences</article-title>
<source>Curr Opin Nephrol Hypertens</source>
<year>2005</year>
<volume>14</volume>
<fpage>543</fpage>
<lpage>549</lpage>
</element-citation></ref>
<ref id="b19-kjim-2018-197">
<label>19</label>
<element-citation publication-type="book">
<person-group person-group-type="author">
<name><surname>Cha</surname><given-names>K</given-names></name>
</person-group>
<source>Principles of bioelectritical impedance analysis</source>
<publisher-loc>Seoul (KR)</publisher-loc>
<publisher-name>InBody Co. Ltd.</publisher-name>
<year>1977</year>
<fpage>1</fpage>
<lpage>8</lpage>
</element-citation></ref>
<ref id="b20-kjim-2018-197">
<label>20</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Matthie</surname><given-names>J</given-names></name>
<name><surname>Zarowitz</surname><given-names>B</given-names></name>
<name><surname>De Lorenzo</surname><given-names>A</given-names></name>
<etal/>
</person-group>
<article-title>Analytic assessment of the various bioimpedance methods used to estimate body water</article-title>
<source>J Appl Physiol (1985)</source>
<year>1998</year>
<volume>84</volume>
<fpage>1801</fpage>
<lpage>1816</lpage>
</element-citation></ref>
<ref id="b21-kjim-2018-197">
<label>21</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Buendia</surname><given-names>R</given-names></name>
<name><surname>Seoane</surname><given-names>F</given-names></name>
<name><surname>Lindecrantz</surname><given-names>K</given-names></name>
<etal/>
</person-group>
<article-title>Estimation of body fluids with bioimpedance spectroscopy: state of the art methods and proposal of novel methods</article-title>
<source>Physiol Meas</source>
<year>2015</year>
<volume>36</volume>
<fpage>2171</fpage>
<lpage>2187</lpage>
</element-citation></ref>
<ref id="b22-kjim-2018-197">
<label>22</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Tattersall</surname><given-names>J</given-names></name>
</person-group>
<article-title>Bioimpedance analysis in dialysis: state of the art and what we can expect</article-title>
<source>Blood Purif</source>
<year>2009</year>
<volume>27</volume>
<fpage>70</fpage>
<lpage>74</lpage>
</element-citation></ref>
<ref id="b23-kjim-2018-197">
<label>23</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Khalil</surname><given-names>SF</given-names></name>
<name><surname>Mohktar</surname><given-names>MS</given-names></name>
<name><surname>Ibrahim</surname><given-names>F</given-names></name>
</person-group>
<article-title>The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases</article-title>
<source>Sensors (Basel)</source>
<year>2014</year>
<volume>14</volume>
<fpage>10895</fpage>
<lpage>10928</lpage>
</element-citation></ref>
<ref id="b24-kjim-2018-197">
<label>24</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Lukaski</surname><given-names>HC</given-names></name>
<name><surname>Bolonchuk</surname><given-names>WW</given-names></name>
<name><surname>Hall</surname><given-names>CB</given-names></name>
<name><surname>Siders</surname><given-names>WA</given-names></name>
</person-group>
<article-title>Validation of tetrapolar bioelectrical impedance method to assess human body composition</article-title>
<source>J Appl Physiol (1985)</source>
<year>1986</year>
<volume>60</volume>
<fpage>1327</fpage>
<lpage>1332</lpage>
</element-citation></ref>
<ref id="b25-kjim-2018-197">
<label>25</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Hannan</surname><given-names>WJ</given-names></name>
<name><surname>Cowen</surname><given-names>SJ</given-names></name>
<name><surname>Plester</surname><given-names>CE</given-names></name>
<name><surname>Fearon</surname><given-names>KC</given-names></name>
<name><surname>deBeau</surname><given-names>A</given-names></name>
</person-group>
<article-title>Comparison of bio-impedance spectroscopy and multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients</article-title>
<source>Clin Sci (Lond)</source>
<year>1995</year>
<volume>89</volume>
<fpage>651</fpage>
<lpage>658</lpage>
</element-citation></ref>
<ref id="b26-kjim-2018-197">
<label>26</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Patel</surname><given-names>RV</given-names></name>
<name><surname>Peterson</surname><given-names>EL</given-names></name>
<name><surname>Silverman</surname><given-names>N</given-names></name>
<name><surname>Zarowitz</surname><given-names>BJ</given-names></name>
</person-group>
<article-title>Estimation of total body and extracellular water in post-coronary artery bypass graft surgical patients using single and multiple frequency bioimpedance</article-title>
<source>Crit Care Med</source>
<year>1996</year>
<volume>24</volume>
<fpage>1824</fpage>
<lpage>1828</lpage>
</element-citation></ref>
<ref id="b27-kjim-2018-197">
<label>27</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Olde Rikkert</surname><given-names>MG</given-names></name>
<name><surname>Deurenberg</surname><given-names>P</given-names></name>
<name><surname>Jansen</surname><given-names>RW</given-names></name>
<name><surname>van&#x00027;t Hof</surname><given-names>MA</given-names></name>
<name><surname>Hoefnagels</surname><given-names>WH</given-names></name>
</person-group>
<article-title>Validation of multi-frequency bioelectrical impedance analysis in detecting changes in fluid balance of geriatric patients</article-title>
<source>J Am Geriatr Soc</source>
<year>1997</year>
<volume>45</volume>
<fpage>1345</fpage>
<lpage>1351</lpage>
</element-citation></ref>
<ref id="b28-kjim-2018-197">
<label>28</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Abbas</surname><given-names>SR</given-names></name>
<name><surname>Zhu</surname><given-names>F</given-names></name>
<name><surname>Levin</surname><given-names>NW</given-names></name>
</person-group>
<article-title>Bioimpedance can solve problems of fluid overload</article-title>
<source>J Ren Nutr</source>
<year>2015</year>
<volume>25</volume>
<fpage>234</fpage>
<lpage>237</lpage>
</element-citation></ref>
<ref id="b29-kjim-2018-197">
<label>29</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Bedogni</surname><given-names>G</given-names></name>
<name><surname>Malavolti</surname><given-names>M</given-names></name>
<name><surname>Severi</surname><given-names>S</given-names></name>
<etal/>
</person-group>
<article-title>Accuracy of an eight-point tactile-electrode impedance method in the assessment of total body water</article-title>
<source>Eur J Clin Nutr</source>
<year>2002</year>
<volume>56</volume>
<fpage>1143</fpage>
<lpage>1148</lpage>
</element-citation></ref>
<ref id="b30-kjim-2018-197">
<label>30</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Chamney</surname><given-names>PW</given-names></name>
<name><surname>Kramer</surname><given-names>M</given-names></name>
<name><surname>Rode</surname><given-names>C</given-names></name>
<name><surname>Kleinekofort</surname><given-names>W</given-names></name>
<name><surname>Wizemann</surname><given-names>V</given-names></name>
</person-group>
<article-title>A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance</article-title>
<source>Kidney Int</source>
<year>2002</year>
<volume>61</volume>
<fpage>2250</fpage>
<lpage>2258</lpage>
</element-citation></ref>
<ref id="b31-kjim-2018-197">
<label>31</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Moissl</surname><given-names>UM</given-names></name>
<name><surname>Wabel</surname><given-names>P</given-names></name>
<name><surname>Chamney</surname><given-names>PW</given-names></name>
<etal/>
</person-group>
<article-title>Body fluid volume determination via body composition spectroscopy in health and disease</article-title>
<source>Physiol Meas</source>
<year>2006</year>
<volume>27</volume>
<fpage>921</fpage>
<lpage>933</lpage>
</element-citation></ref>
<ref id="b32-kjim-2018-197">
<label>32</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Chertow</surname><given-names>GM</given-names></name>
<name><surname>Lowrie</surname><given-names>EG</given-names></name>
<name><surname>Wilmore</surname><given-names>DW</given-names></name>
<etal/>
</person-group>
<article-title>Nutritional assessment with bioelectrical impedance analysis in maintenance hemodialysis patients</article-title>
<source>J Am Soc Nephrol</source>
<year>1995</year>
<volume>6</volume>
<fpage>75</fpage>
<lpage>81</lpage>
</element-citation></ref>
<ref id="b33-kjim-2018-197">
<label>33</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Zhu</surname><given-names>F</given-names></name>
<name><surname>Wystrychowski</surname><given-names>G</given-names></name>
<name><surname>Kitzler</surname><given-names>T</given-names></name>
<name><surname>Thijssen</surname><given-names>S</given-names></name>
<name><surname>Kotanko</surname><given-names>P</given-names></name>
<name><surname>Levin</surname><given-names>NW</given-names></name>
</person-group>
<article-title>Application of bioimpedance techniques to peritoneal dialysis</article-title>
<source>Contrib Nephrol</source>
<year>2006</year>
<volume>150</volume>
<fpage>119</fpage>
<lpage>128</lpage>
</element-citation></ref>
<ref id="b34-kjim-2018-197">
<label>34</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Asghar</surname><given-names>RB</given-names></name>
<name><surname>Green</surname><given-names>S</given-names></name>
<name><surname>Engel</surname><given-names>B</given-names></name>
<name><surname>Davies</surname><given-names>SJ</given-names></name>
</person-group>
<article-title>Relationship of demographic, dietary, and clinical factors to the hydration status of patients on peritoneal dialysis</article-title>
<source>Perit Dial Int</source>
<year>2004</year>
<volume>24</volume>
<fpage>231</fpage>
<lpage>239</lpage>
</element-citation></ref>
<ref id="b35-kjim-2018-197">
<label>35</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Lindley</surname><given-names>E</given-names></name>
<name><surname>Devine</surname><given-names>Y</given-names></name>
<name><surname>Hall</surname><given-names>L</given-names></name>
<etal/>
</person-group>
<article-title>A ward-based procedure for assessment of fluid status in peritoneal dialysis patients using bioimpedance spectroscopy</article-title>
<source>Perit Dial Int</source>
<year>2005</year>
<volume>25 Suppl 3</volume>
<fpage>S46</fpage>
<lpage>S48</lpage>
</element-citation></ref>
<ref id="b36-kjim-2018-197">
<label>36</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Davies</surname><given-names>SJ</given-names></name>
<name><surname>Davenport</surname><given-names>A</given-names></name>
</person-group>
<article-title>The role of bioimpedance and biomarkers in helping to aid clinical decision-making of volume assessments in dialysis patients</article-title>
<source>Kidney Int</source>
<year>2014</year>
<volume>86</volume>
<fpage>489</fpage>
<lpage>496</lpage>
</element-citation></ref>
<ref id="b37-kjim-2018-197">
<label>37</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Konings</surname><given-names>CJ</given-names></name>
<name><surname>Kooman</surname><given-names>JP</given-names></name>
<name><surname>Schonck</surname><given-names>M</given-names></name>
<etal/>
</person-group>
<article-title>Fluid status, blood pressure, and cardiovascular abnormalities in patients on peritoneal dialysis</article-title>
<source>Perit Dial Int</source>
<year>2002</year>
<volume>22</volume>
<fpage>477</fpage>
<lpage>487</lpage>
</element-citation></ref>
<ref id="b38-kjim-2018-197">
<label>38</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>van de Kerkhof</surname><given-names>J</given-names></name>
<name><surname>Hermans</surname><given-names>M</given-names></name>
<name><surname>Beerenhout</surname><given-names>C</given-names></name>
<etal/>
</person-group>
<article-title>Reference values for multifrequency bioimpedance analysis in dialysis patients</article-title>
<source>Blood Purif</source>
<year>2004</year>
<volume>22</volume>
<fpage>301</fpage>
<lpage>306</lpage>
</element-citation></ref>
<ref id="b39-kjim-2018-197">
<label>39</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Wang</surname><given-names>X</given-names></name>
<name><surname>Axelsson</surname><given-names>J</given-names></name>
<name><surname>Lindholm</surname><given-names>B</given-names></name>
<name><surname>Wang</surname><given-names>T</given-names></name>
</person-group>
<article-title>Volume status and blood pressure in continuous ambulatory peritoneal dialysis patients</article-title>
<source>Blood Purif</source>
<year>2005</year>
<volume>23</volume>
<fpage>373</fpage>
<lpage>378</lpage>
</element-citation></ref>
<ref id="b40-kjim-2018-197">
<label>40</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Plum</surname><given-names>J</given-names></name>
<name><surname>Schoenicke</surname><given-names>G</given-names></name>
<name><surname>Kleophas</surname><given-names>W</given-names></name>
<etal/>
</person-group>
<article-title>Comparison of body fluid distribution between chronic haemodialysis and peritoneal dialysis patients as assessed by biophysical and biochemical methods</article-title>
<source>Nephrol Dial Transplant</source>
<year>2001</year>
<volume>16</volume>
<fpage>2378</fpage>
<lpage>2385</lpage>
</element-citation></ref>
<ref id="b41-kjim-2018-197">
<label>41</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Piccoli</surname><given-names>A</given-names></name>
</person-group>
<article-title>Whole body: single frequency bioimpedance</article-title>
<source>Contrib Nephrol</source>
<year>2005</year>
<volume>149</volume>
<fpage>150</fpage>
<lpage>161</lpage>
</element-citation></ref>
<ref id="b42-kjim-2018-197">
<label>42</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Piccoli</surname><given-names>A</given-names></name>
<name><surname>Rossi</surname><given-names>B</given-names></name>
<name><surname>Pillon</surname><given-names>L</given-names></name>
<name><surname>Bucciante</surname><given-names>G</given-names></name>
</person-group>
<article-title>A new method for monitoring body fluid variation by bioimpedance analysis: the RXc graph</article-title>
<source>Kidney Int</source>
<year>1994</year>
<volume>46</volume>
<fpage>534</fpage>
<lpage>539</lpage>
</element-citation></ref>
<ref id="b43-kjim-2018-197">
<label>43</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Chamney</surname><given-names>PW</given-names></name>
<name><surname>Wabel</surname><given-names>P</given-names></name>
<name><surname>Moissl</surname><given-names>UM</given-names></name>
<etal/>
</person-group>
<article-title>A whole-body model to distinguish excess fluid from the hydration of major body tissues</article-title>
<source>Am J Clin Nutr</source>
<year>2007</year>
<volume>85</volume>
<fpage>80</fpage>
<lpage>89</lpage>
</element-citation></ref>
<ref id="b44-kjim-2018-197">
<label>44</label>
<element-citation publication-type="book">
<person-group person-group-type="author">
<name><surname>Fresenius Medical</surname><given-names>Care</given-names></name>
</person-group>
<source>BCM standard</source>
<publisher-loc>Bad Homburg (DE)</publisher-loc>
<publisher-name>Fresenius Medical Care</publisher-name>
<year>2014</year>
</element-citation></ref>
<ref id="b45-kjim-2018-197">
<label>45</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Onofriescu</surname><given-names>M</given-names></name>
<name><surname>Hogas</surname><given-names>S</given-names></name>
<name><surname>Voroneanu</surname><given-names>L</given-names></name>
<etal/>
</person-group>
<article-title>Bioimpedance-guided fluid management in maintenance hemodialysis: a pilot randomized controlled trial</article-title>
<source>Am J Kidney Dis</source>
<year>2014</year>
<volume>64</volume>
<fpage>111</fpage>
<lpage>118</lpage>
</element-citation></ref>
<ref id="b46-kjim-2018-197">
<label>46</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Chen</surname><given-names>YC</given-names></name>
<name><surname>Chen</surname><given-names>HH</given-names></name>
<name><surname>Yeh</surname><given-names>JC</given-names></name>
<name><surname>Chen</surname><given-names>SY</given-names></name>
</person-group>
<article-title>Adjusting dry weight by extracellular volume and body composition in hemodialysis patients</article-title>
<source>Nephron</source>
<year>2002</year>
<volume>92</volume>
<fpage>91</fpage>
<lpage>96</lpage>
</element-citation></ref>
<ref id="b47-kjim-2018-197">
<label>47</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Pillon</surname><given-names>L</given-names></name>
<name><surname>Piccoli</surname><given-names>A</given-names></name>
<name><surname>Lowrie</surname><given-names>EG</given-names></name>
<name><surname>Lazarus</surname><given-names>JM</given-names></name>
<name><surname>Chertow</surname><given-names>GM</given-names></name>
</person-group>
<article-title>Vector length as a proxy for the adequacy of ultrafiltration in hemodialysis</article-title>
<source>Kidney Int</source>
<year>2004</year>
<volume>66</volume>
<fpage>1266</fpage>
<lpage>1271</lpage>
</element-citation></ref>
<ref id="b48-kjim-2018-197">
<label>48</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Piccoli</surname><given-names>A</given-names></name>
</person-group>
<article-title>Identification of operational clues to dry weight prescription in hemodialysis using bioimpedance vector analysis. The Italian Hemodialysis-Bioelectrical Impedance Analysis (HD-BIA) Study Group</article-title>
<source>Kidney Int</source>
<year>1998</year>
<volume>53</volume>
<fpage>1036</fpage>
<lpage>1043</lpage>
</element-citation></ref>
<ref id="b49-kjim-2018-197">
<label>49</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Onofriescu</surname><given-names>M</given-names></name>
<name><surname>Siriopol</surname><given-names>D</given-names></name>
<name><surname>Voroneanu</surname><given-names>L</given-names></name>
<etal/>
</person-group>
<article-title>Overhydration, cardiac function and survival in hemodialysis patients</article-title>
<source>PLoS One</source>
<year>2015</year>
<volume>10</volume>
<elocation-id>e0135691</elocation-id>
</element-citation></ref>
<ref id="b50-kjim-2018-197">
<label>50</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Machek</surname><given-names>P</given-names></name>
<name><surname>Jirka</surname><given-names>T</given-names></name>
<name><surname>Moissl</surname><given-names>U</given-names></name>
<name><surname>Chamney</surname><given-names>P</given-names></name>
<name><surname>Wabel</surname><given-names>P</given-names></name>
</person-group>
<article-title>Guided optimization of fluid status in haemodialysis patients</article-title>
<source>Nephrol Dial Transplant</source>
<year>2010</year>
<volume>25</volume>
<fpage>538</fpage>
<lpage>544</lpage>
</element-citation></ref>
<ref id="b51-kjim-2018-197">
<label>51</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Moissl</surname><given-names>U</given-names></name>
<name><surname>Arias-Guillen</surname><given-names>M</given-names></name>
<name><surname>Wabel</surname><given-names>P</given-names></name>
<etal/>
</person-group>
<article-title>Bioimpedance-guided fluid management in hemodialysis patients</article-title>
<source>Clin J Am Soc Nephrol</source>
<year>2013</year>
<volume>8</volume>
<fpage>1575</fpage>
<lpage>1582</lpage>
</element-citation></ref>
<ref id="b52-kjim-2018-197">
<label>52</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Zhu</surname><given-names>F</given-names></name>
<name><surname>Kuhlmann</surname><given-names>MK</given-names></name>
<name><surname>Sarkar</surname><given-names>S</given-names></name>
<etal/>
</person-group>
<article-title>Adjustment of dry weight in hemodialysis patients using intradialytic continuous multifrequency bioimpedance of the calf</article-title>
<source>Int J Artif Organs</source>
<year>2004</year>
<volume>27</volume>
<fpage>104</fpage>
<lpage>109</lpage>
</element-citation></ref>
<ref id="b53-kjim-2018-197">
<label>53</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Oe</surname><given-names>B</given-names></name>
<name><surname>De Fijter</surname><given-names>CW</given-names></name>
<name><surname>Geers</surname><given-names>TB</given-names></name>
<name><surname>Vos</surname><given-names>PF</given-names></name>
<name><surname>de Vries</surname><given-names>PM</given-names></name>
</person-group>
<article-title>Hemodialysis (HD) versus peritoneal dialysis (PD): latent overhydration in PD patients?</article-title>
<source>Int J Artif Organs</source>
<year>2002</year>
<volume>25</volume>
<fpage>838</fpage>
<lpage>843</lpage>
</element-citation></ref>
<ref id="b54-kjim-2018-197">
<label>54</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>O&#x02019;Lone</surname><given-names>EL</given-names></name>
<name><surname>Visser</surname><given-names>A</given-names></name>
<name><surname>Finney</surname><given-names>H</given-names></name>
<name><surname>Fan</surname><given-names>SL</given-names></name>
</person-group>
<article-title>Clinical significance of multi-frequency bioimpedance spectroscopy in peritoneal dialysis patients: independent predictor of patient survival</article-title>
<source>Nephrol Dial Transplant</source>
<year>2014</year>
<volume>29</volume>
<fpage>1430</fpage>
<lpage>1437</lpage>
</element-citation></ref>
<ref id="b55-kjim-2018-197">
<label>55</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Yoon</surname><given-names>HE</given-names></name>
<name><surname>Kwon</surname><given-names>YJ</given-names></name>
<name><surname>Song</surname><given-names>HC</given-names></name>
<etal/>
</person-group>
<article-title>Overhydration negatively affects quality of life in peritoneal dialysis patients: evidence from a prospective observational study</article-title>
<source>Int J Med Sci</source>
<year>2016</year>
<volume>13</volume>
<fpage>686</fpage>
<lpage>695</lpage>
</element-citation></ref>
<ref id="b56-kjim-2018-197">
<label>56</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Jang</surname><given-names>M</given-names></name>
<name><surname>Kim</surname><given-names>WH</given-names></name>
<name><surname>Lee</surname><given-names>JH</given-names></name>
<etal/>
</person-group>
<article-title>Numerical expression of volume status using the bioimpedance ratio in continuous ambulatory peritoneal dialysis patients: a pilot study</article-title>
<source>Kidney Res Clin Pract</source>
<year>2017</year>
<volume>36</volume>
<fpage>290</fpage>
<lpage>295</lpage>
</element-citation></ref>
<ref id="b57-kjim-2018-197">
<label>57</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Foley</surname><given-names>RN</given-names></name>
<name><surname>Parfrey</surname><given-names>PS</given-names></name>
<name><surname>Morgan</surname><given-names>J</given-names></name>
<etal/>
</person-group>
<article-title>Effect of hemoglobin levels in hemodialysis patients with asymptomatic cardiomyopathy</article-title>
<source>Kidney Int</source>
<year>2000</year>
<volume>58</volume>
<fpage>1325</fpage>
<lpage>1335</lpage>
</element-citation></ref>
<ref id="b58-kjim-2018-197">
<label>58</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Hur</surname><given-names>E</given-names></name>
<name><surname>Usta</surname><given-names>M</given-names></name>
<name><surname>Toz</surname><given-names>H</given-names></name>
<etal/>
</person-group>
<article-title>Effect of fluid management guided by bioimpedance spectroscopy on cardiovascular parameters in hemodialysis patients: a randomized controlled trial</article-title>
<source>Am J Kidney Dis</source>
<year>2013</year>
<volume>61</volume>
<fpage>957</fpage>
<lpage>965</lpage>
</element-citation></ref>
<ref id="b59-kjim-2018-197">
<label>59</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Middleton</surname><given-names>RJ</given-names></name>
<name><surname>Parfrey</surname><given-names>PS</given-names></name>
<name><surname>Foley</surname><given-names>RN</given-names></name>
</person-group>
<article-title>Left ventricular hypertrophy in the renal patient</article-title>
<source>J Am Soc Nephrol</source>
<year>2001</year>
<volume>12</volume>
<fpage>1079</fpage>
<lpage>1084</lpage>
</element-citation></ref>
<ref id="b60-kjim-2018-197">
<label>60</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Chazot</surname><given-names>C</given-names></name>
<name><surname>Wabel</surname><given-names>P</given-names></name>
<name><surname>Chamney</surname><given-names>P</given-names></name>
<name><surname>Moissl</surname><given-names>U</given-names></name>
<name><surname>Wieskotten</surname><given-names>S</given-names></name>
<name><surname>Wizemann</surname><given-names>V</given-names></name>
</person-group>
<article-title>Importance of normohydration for the long-term survival of haemodialysis patients</article-title>
<source>Nephrol Dial Transplant</source>
<year>2012</year>
<volume>27</volume>
<fpage>2404</fpage>
<lpage>2410</lpage>
</element-citation></ref>
</ref-list>
<sec sec-type="display-objects">
<title>Figures</title>
<fig id="f1-kjim-2018-197" position="float">
<label>Figure 1.</label><caption><p>Current flows in tissue at low and high frequencies. Reproduced by courtesy of InBody &#x0005b;<xref ref-type="bibr" rid="b19-kjim-2018-197">19</xref>&#x0005d;. ICW, intracellular water; ECW, extracellular water.</p></caption>
<graphic xlink:href="kjim-2018-197f1.tif"/>
</fig>
<fig id="f2-kjim-2018-197" position="float">
<label>Figure 2.</label><caption><p>Measurement of body impedance. Reproduced by courtesy of InBody &#x0005b;<xref ref-type="bibr" rid="b19-kjim-2018-197">19</xref>&#x0005d;. </p></caption>
<graphic xlink:href="kjim-2018-197f2.tif"/>
</fig>
<fig id="f3-kjim-2018-197" position="float">
<label>Figure 3.</label><caption><p>Measurement pathways of a segmental bioimpedance analysis device. Reproduced by courtesy of InBody &#x0005b;<xref ref-type="bibr" rid="b19-kjim-2018-197">19</xref>&#x0005d;.</p></caption>
<graphic xlink:href="kjim-2018-197f3.tif"/>
</fig>
<fig id="f4-kjim-2018-197" position="float">
<label>Figure 4.</label><caption><p>Relationship between normovolemic slope (S<sub>NV</sub>) and hypervolemic slope (S<sub>HV</sub>) with respect to body weight. Dry weight is indicated at the intersection of the S<sub>NV</sub> and S<sub>HV</sub> slopes. Modified from Chamney et al., with permission of Elsevier Inc. &#x0005b;<xref ref-type="bibr" rid="b30-kjim-2018-197">30</xref>&#x0005d;.</p></caption>
<graphic xlink:href="kjim-2018-197f4.tif"/>
</fig>
<fig id="f5-kjim-2018-197" position="float">
<label>Figure 5.</label><caption><p><italic>R</italic> and <italic>Xc</italic>, normalized for height, are plotted on the RXc graph with elliptical probability regions (50%, 75%, and 95% tolerance ellipses). Vector movement along the major axis of ellipses means changes in hydration status. Modified from Piccoli, with permission of Karger Publishers &#x0005b;<xref ref-type="bibr" rid="b41-kjim-2018-197">41</xref>&#x0005d;. <italic>R</italic>, resistance; <italic>Xc</italic>, reactance; <italic>H</italic>, height.</p></caption>
<graphic xlink:href="kjim-2018-197f5.tif"/>
</fig>
<fig id="f6-kjim-2018-197" position="float">
<label>Figure 6.</label><caption><p>The volume model describes electrical conductance in a cell suspension enabling the total body water (TBW), extracellular water (ECW), and intracellular water (ICW) to be calculated. The body composition model is used for calculating the three relevant body compartments, namely overhydration, lean tissue, and adipose tissue, from ECW and TBW information. Reproduced by courtesy of Fresenius Medical Care &#x0005b;<xref ref-type="bibr" rid="b44-kjim-2018-197">44</xref>&#x0005d;.</p></caption>
<graphic xlink:href="kjim-2018-197f6.tif"/>
</fig>
<fig id="f7-kjim-2018-197" position="float">
<label>Figure 7.</label><caption><p>The calf-bioimpedance spectroscopy method that is used to estimate dry weight. The line represents the continuous value of the extracellular resistance ratio (<italic>R<sub>0</sub>/R<sub>t</sub></italic>). The flattening of the curve indicates that the excessive extracellular water in the patient’s calf had been removed. Dry weight is defined as the flattening of the curve over a period of 20 minutes. Modified from Zhu et al. with permission of SAGE Publications &#x0005b;<xref ref-type="bibr" rid="b52-kjim-2018-197">52</xref>&#x0005d;.</p></caption>
<graphic xlink:href="kjim-2018-197f7.tif"/>
</fig>
</sec>
</back></article>